Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: TC-RES-0324-01452
Parcel: 138080190

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0324-01452
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/12/2024 Fire New Construction NOT REQUIRED
03/21/2024 Site Engineering NOT REQUIRED
03/21/2024 Site Landscape NOT REQUIRED
04/03/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/21/2024 Residential Building REQUIRES RESUBMIT Permit Review TC-RES-0324-01452 (757 W CALLE ANTONIA TUCSON, AZ 85706)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC).

1. Provide a ledger detail. Show ledger to wall connections consistent with Figure R606.11 (1).
2. Show size, spacing and span of all framing members, trusses, joists, rafters, beams, glue-lams, lintels, headers, ledgers and blocking, R301.1. >> provide porch depth measurements and span.
3. Provide a complete roof framing plan with the corner ridge beam sized with appropriate load carrying capacity. Design ridge structural member that supports rafters as a beam when the roof pitch is less than 3” to 12”, R802.3. Or show roof structural members with rafter ties (or ceiling joists) and collar ties (ridge straps) when the roof pitch is equal or greater than 3” to 12”, R802.3. >> provide a corner ridge beam detail showing rafters connections.
4. Provide a measurement from the face of the porch structure to the property line for fire separation compliance verification. R302.1 (City of Tucson Amended)

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
04/03/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Nathan Herrera
Lead Planner

PROJECT: TC-RES-0324-01452
Address: 757 W Calle Antonia. Tucson, AZ. 85706
Parcel: 138-08-0190
Zoning: R-1
Existing Use: Single Family Residence
Project Description: Ramada/Porch Replacement

TRANSMITTAL DATE: 04/03/2024

1. COMMENT: Provide a site plan that meets the Residential Plot Plan Requirements. An example can be found at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: revised residential building permit along with a detailed response letter, which states how all Zoning Review Section comments were addressed. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf

If you have any questions about this transmittal, please contact Nathan Herrera at Nathan.Herrera@TucsonAZ.gov or at 520-837-4894.
03/12/2024 PDSD Application Completeness Express REVIEW COMPLETED