Permit Number: TC-RES-0324-01439
Parcel: 138090510

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0324-01439
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/07/2025 Site Engineering NOT REQUIRED
01/27/2025 Site Landscape NOT REQUIRED
02/07/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/26/2025 Fire New Construction PENDING ASSIGNMENT
01/27/2025 Residential Building REQUIRES RESUBMIT Permit Review TC-RES-0324-01439 (205 W CALLE PRIMER HOGAR TUCSON, AZ 85706)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2018 International Building Code (IBC), 2017 National Electrical Code (NEC).

>>> The following comment was not addressed: See sheet 3 ‘Section &Elevation Plan’ note 10.

1. Provide framing details to show the attachment of new roof structures to existing structure. The rafters are required to either sit directly over a load bearing wall or be attached to a ledger on the load bearing wall. >>> Cannot have the attachment to the Fascia. Fascia is not a load bearing component.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
02/06/2025 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-0324-01439
205 W Calle Primer Hogar - R-1
Porch Addition

TRANSMITTAL DATE: February 6, 2025

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6,9,10.

1. The north/south property dimensions shown on the plot plan are not correct. Review the Casa Primera final plat found at: https://maps-and-records.tucsonaz.gov/subdivisions/details/5419, and provide the correct dimensions.

2. Per UDC Table 6.3-2.A the minimum setback from the “(N) STORAGE” shown on the plot plan to the east property line is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line. Based on a wall height of less than 9’-0” the required perimeter yard setback from the storage to the east property line is 6’-0”, proposed setback is 4’-0”. At a minimum a neighbors setback waiver is required, UDC Article 6.6.2.D. To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the property owner at 193 W. Calle Primer Hogar:
My Name is____________________ and I am the owner of the property located at 193 W. Calle Primer Hogar. I have reviewed the site plan and I have no objection to structure being located or constructed 4’-0” from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
01/26/2025 PDSD Application Completeness Express REVIEW COMPLETED