| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/11/2024 | Light Residential Building Review (OIP) | APPROVED | Approved with Notes and details added to plans. All fire access and pathways shall comply with R324.6. Fire Access and pathways: 1.Provide two pathways, on separate roof planes from lowest roof edge and not less than 36” wide. R324.6.1. 2.For each roof plane with a photovoltaic array, a pathway not less than 36” wide shall be provided from the roof access point to the horizontal ridge. R324.6.1 3.For photovoltaic arrays occupying not more than 33% of the plan view total roof area, not less than an 18” clear setback is required on both sides of a horizontal ridge. R324.6.2. |
||
| 07/01/2024 | Site Engineering | APPROVED | |||
| 07/01/2024 | Bldg Permits - Post Review Express | REVIEW COMPLETED | |||
| 06/04/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |