Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0324-01391
Parcel: 13331094A

Address:
311 S PORTER AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SOLAR v.1

Permit Number - TC-RES-0324-01391
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/09/2024 Site Engineering NOT REQUIRED
04/09/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/20/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0324-01391 (311 S PORTER AV TUCSON, AZ 85710)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC).

1. The inspections for the detached garage need to be completed prior to solar approval. TC-RES-0523-04878 (311 S PORTER AV TUCSON, AZ 85710)
2. Provide a Grounding Electrode System at the detached structure per NEC 690.47.
3. Show grounding details for the mounting equipment and metal support frame, NEC690.43.
4. Non-listed equipment for mounting and attachments to the roof must include a design and seal by an Arizona Registrant, for wind uplift and attatchment. IBC 107.1.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
03/11/2024 PDSD Application Completeness Express REVIEW COMPLETED