Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0324-01372
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/13/2024 | Fire New Construction | NOT REQUIRED | |||
| 04/05/2024 | Site Engineering | NOT REQUIRED | |||
| 04/08/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/19/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0324-01372 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Provide a complete plan set as identified at the Index of Drawings, sheet A0.1. Remove the “Preliminary Not for Construction” stamp from each title block. SITE PLAN: Provide a site plan showing utilities for the dwelling, R106.1.1. PLANS: 1. Clarify the appropriate metal covering lap sealant for the roof slope consistent with R905.10. Provide additional notation for the Roof Plan coverings, sheet A1.0, R301.1. SECTIONS - DETAILS: 1. Provide a detail of the infill framing as noted on the Floor Plan sheet A1.0, R106.1. 2. Provide keynote markings at the elevations, sheet A2.0, R106.1. 3. Provide structural roof sheathing and fastening in compliance with Table R602.3 (1). 4. Identify joist hangers, R802.11. OUTDOOR LIGHTING CODE Show any proposed fixtures as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 04/08/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0324-01372 850 North Barbara Worth – R-1 Carport (1st Review) TRANSMITTAL DATE: April 8, 2024 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. The site is in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in the R-1 zone, subject to use-specific standards 4.9.7.B.5-.9. 1. Provide a site plan that meets the residential plot plan requirements found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf. The requirements are provided in both graphic and written formats. 2. Include dimensions on Sheet A2.0 measured from the design grade elevation to the highest point of the structural elements supporting the carport roof. Per Tucson Unified Development Code (UDC) Table 6.3-2.A, the required interior perimeter yards are six feet or 2/3 the height of the exterior building wall, whichever is greater, measured from the interior lot lines. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 03/08/2024 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 03/19/2024 | Site Landscape | REVIEW COMPLETED |