Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0324-01305
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/19/2024 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0324-01305 (3307 N OLSEN AV TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC). Clarify if the structure is a sleeping quarters (without kitchen) or an Accessory Dwelling Unit (ADU) which requires many alterations for compliance. An independent dwelling (ADU) requires fire spread and utility (electrical & water) separation so that one dwelling is not dependent upon another for water or electrical service. Each dwelling unit with kitchen requires a separate Pima County assigned street address after Zoning approval, R319. Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512 An impact fee payment is required for an ADU at the time of permit payment. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc. General Review: 1. Show compliance with R310 providing egress from bedrooms with minimum net clear opening area of 5.7 SQ FT (5 SQ FT 1st floor). Also, show the minimum net clear opening dimension of 24” height and 20” width, and maximum sill height of 44”. 2. Show one-hour fire-resistive framed construction separating dwellings in compliance with IBC Table 721.1(2). 3. Fire separation between two dwelling walls. Requires a compliant fire wall from foundation to roof sheathing, R302.3. A compliant fire wall has no openings for windows or doors. R302.1. SECTIONS - DETAILS: 4. Show a cross-section detail of the proposed exterior in-fill wall, R106.1.1. Show 3/8” structural or ½” non-structural wall sheathing of the proposed exterior in-fill wall, R106.1.1. 5. Show a complete cross-section detail of the new exterior in-fill wall, R106.1.1. Show the minimum 12” x 12” continuous #4 rebar reinforced footing, R403.1. Show with dimensions the exterior wood siding, insulation, interior sheathing, and pressure treated sill anchored with ½” x 10” bolts. Show the wall assembly with a 6” clearance above the ground or 2” clearance above an exterior concrete surface, R317.1 item 5. 6. The framed wall may require a concrete stem for achieving the 6” clearance between framing and ground (R317.1 item 5). 7. Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. 8. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing (closed cell spray or rigid board tight to the roof sheathing), R806.5. This condensation control provision is necessary for code compliance and may be a single layer of air-impermeable insulation or layered with batt insulation for achieving the total required roof R-value. See ‘TYP ROOF SECTION’ on sheet A1.1. Plumbing Review: 10. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate existing or proposed water meter size. 11. Provide a complete fixture unit schedule, for both the proposed new ADU and the existing main dwelling, P2903.6. Provide the water pipe diameter between the meter and shut off valve in compliance with P2903.7. A minimum 1” service pipe is required for supplying water to more than 9.5 fixture units. 12. Updated Key Note #9 on sheet A1.5 to Show fiber-cement board or glass mat gypsum backers for tiled walls in tub and shower areas, R702.4.2. 13. Show the platform mounted water heater with a listed pan and ¾” drain line to a waste receptor or to the building exterior 6” above grade, P2801.6. 14. Show a pressure and temperature relief valve at the water heater. Note a metallic T&P line terminating at the exterior 6 inches above grade facing down, P2803.6.1. 15. Show an individual accessible water supply shut off for each dwelling unit, P2903.9.1. Electrical Review: 16. Provide electrical load calculations for the existing main service panel, for determining the service panel size, E3602.2. 17. Provide a minimum service conductor rating of 100 AMP for the ADU dwelling and conductors with minimum rating of #4 copper 75 degree C, E3602.1 & E3603.1. 18. Show sub-panel feeder conductor and conduit sizes with appropriate correction factors, E3705. Also provide the sub-panel OCPD at the source, E3705.5. 19. Show a GFCI receptacle outlet on the same level within 25’ of exterior HVAC equipment, E3901.12. 20. Show Combination ARC Fault protection for all circuits listed in E3902.16. All Arc Fault circuit interrupters shall be installed in readily accessible locations, E3902.15. Also update Electrical General Notes # 7 to reference the correct code and locations. Update note 9 to remove the ‘Non-GFCI Circuits’ reference. 21. Show Ground-Fault Circuit-Interrupter (GFCI) protection for all receptacles as required in E3902. Including, all bathroom, washer/laundry area, dishwasher/disposal, kitchen countertop, etc. Update Electrical General Notes # 6 to show GFCI required when within 6’ of a sink per E3902.7. 22. Show at least one wall-switch-controlled lighting outlet providing illumination on the exterior side of each egress door having grade level access R3903.3. Carport Review: 23. Roof framing spans exceeding 20 feet require a registered engineer design, ARS 32-144.A.4. The provided glulam beam span is 23’ 2”. Provide the glulam beam’s size and type for structural verification. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 03/19/2024 | PDSD Application Completeness Express | VOID | Permit Review TC-RES-0324-01305 (3307 N OLSEN AV TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC). Clarify if the structure is a sleeping quarters (without kitchen) or an Accessory Dwelling Unit (ADU) which requires many alterations for compliance. An independent dwelling (ADU) requires fire spread and utility (electrical & water) separation so that one dwelling is not dependent upon another for water or electrical service. Each dwelling unit with kitchen requires a separate Pima County assigned street address after Zoning approval, R319. Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512 An impact fee payment is required for an ADU at the time of permit payment. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc. General Review: 1. Show compliance with R310 providing egress from bedrooms with minimum net clear opening area of 5.7 SQ FT (5 SQ FT 1st floor). Also, show the minimum net clear opening dimension of 24” height and 20” width, and maximum sill height of 44”. 2. Show one-hour fire-resistive framed construction separating dwellings in compliance with IBC Table 721.1(2). 3. Fire separation between two dwelling walls. Requires a compliant fire wall from foundation to roof sheathing, R302.3. A compliant fire wall has no openings for windows or doors. R302.1. SECTIONS - DETAILS: 4. Show a cross-section detail of the proposed exterior in-fill wall, R106.1.1. Show 3/8” structural or ½” non-structural wall sheathing of the proposed exterior in-fill wall, R106.1.1. 5. Show a complete cross-section detail of the new exterior in-fill wall, R106.1.1. Show the minimum 12” x 12” continuous #4 rebar reinforced footing, R403.1. Show with dimensions the exterior wood siding, insulation, interior sheathing, and pressure treated sill anchored with ½” x 10” bolts. Show the wall assembly with a 6” clearance above the ground or 2” clearance above an exterior concrete surface, R317.1 item 5. 6. The framed wall may require a concrete stem for achieving the 6” clearance between framing and ground (R317.1 item 5). 7. Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. 8. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing (closed cell spray or rigid board tight to the roof sheathing), R806.5. This condensation control provision is necessary for code compliance and may be a single layer of air-impermeable insulation or layered with batt insulation for achieving the total required roof R-value. See ‘TYP ROOF SECTION’ on sheet A1.1. Plumbing Review: 10. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate existing or proposed water meter size. 11. Provide a complete fixture unit schedule, for both the proposed new ADU and the existing main dwelling, P2903.6. Provide the water pipe diameter between the meter and shut off valve in compliance with P2903.7. A minimum 1” service pipe is required for supplying water to more than 9.5 fixture units. 12. Updated Key Note #9 on sheet A1.5 to Show fiber-cement board or glass mat gypsum backers for tiled walls in tub and shower areas, R702.4.2. 13. Show the platform mounted water heater with a listed pan and ¾” drain line to a waste receptor or to the building exterior 6” above grade, P2801.6. 14. Show a pressure and temperature relief valve at the water heater. Note a metallic T&P line terminating at the exterior 6 inches above grade facing down, P2803.6.1. 15. Show an individual accessible water supply shut off for each dwelling unit, P2903.9.1. Electrical Review: 16. Provide electrical load calculations for the existing main service panel, for determining the service panel size, E3602.2. 17. Provide a minimum service conductor rating of 100 AMP for the ADU dwelling and conductors with minimum rating of #4 copper 75 degree C, E3602.1 & E3603.1. 18. Show sub-panel feeder conductor and conduit sizes with appropriate correction factors, E3705. Also provide the sub-panel OCPD at the source, E3705.5. 19. Show a GFCI receptacle outlet on the same level within 25’ of exterior HVAC equipment, E3901.12. 20. Show Combination ARC Fault protection for all circuits listed in E3902.16. All Arc Fault circuit interrupters shall be installed in readily accessible locations, E3902.15. Also update Electrical General Notes # 7 to reference the correct code and locations. Update note 9 to remove the ‘Non-GFCI Circuits’ reference. 21. Show Ground-Fault Circuit-Interrupter (GFCI) protection for all receptacles as required in E3902. Including, all bathroom, washer/laundry area, dishwasher/disposal, kitchen countertop, etc. Update Electrical General Notes # 6 to show GFCI required when within 6’ of a sink per E3902.7. 22. Show at least one wall-switch-controlled lighting outlet providing illumination on the exterior side of each egress door having grade level access R3903.3. Carport Review: 23. Roof framing spans exceeding 20 feet require a registered engineer design, ARS 32-144.A.4. The provided glulam beam span is 23’ 2”. Provide the glulam beam’s size and type for structural verification. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |