Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-0324-01304
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/04/2024 | Site Engineering | NOT REQUIRED | |||
04/04/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
03/19/2024 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Mobil/Manufactured Homes require an analysis and seal of an Arizona Registered Registrant for verifying the structure can support the additional loads associated with a PV installation. Provide the engineer structural letter of the complete roof framing information for determining load carrying capacity for the roof structure. Show all load bearing locations. Demonstrate the ability for supporting the existing and additional dead load, and provide an engineer’s calculation, design, and seal for verifying the truss load carrying capacity. R324.4 Equipment shall be positively attached to the roof structure with a minimum of one connection per 10 sf of equipment (minimum of two connections per piece of equipment). Point loads exceeding 40 lbs shall require a structural load analysis by licensed Arizona engineer. R106.1 and R301.1.3 Building_Official@tucsonaz.gov |
||
03/05/2024 | PDSD Application Completeness | REVIEW COMPLETED |