Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0324-01252
Parcel: 126050350

Address:
4041 E 1ST ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0324-01252
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/14/2024 Residential Building APPROVED
04/02/2024 Site Engineering NOT REQUIRED
04/05/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/05/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Nathan Herrera
Planner

PROJECT: TC-RES-0324-01252
Address: 4041 E 1ST ST TUCSON, AZ 85711
Parcel: 126-05-0350
Zoning: R-1
Existing Use: Single Family Residence
Project Description: Detached Sleeping Quarters/SFR Addition

TRANSMITTAL DATE: 4/05/2024

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.


1. COMMENT: Per UDC Article 6.6.3.E, The total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure.

As shown on the site plan, the square footage provided for the proposed sleeping quarters existing one car garage exceed 50% gfa of the principal structure of the property.

A Board of Adjustment Variance process will need to be applied for and approved to allow for the proposed addition to the existing garage.

Alternatively, the garage can be connected to the main house through a structural element that is at least 5 feet wide and can support a 20 pound live load. If the existing garage and proposed addition to the structure can be connected to the main house through the above described structural element a Variance will not be required.

2. COMMENT: Add the “Proposed Addition” to the existing SFR to the Lot Coverage Calculation.

3. COMMENT: Per UDC Article 6.3-2.A, the required setbacks in the R-1 zone are the greater of 6 feet or 2/3 the height of the building wall.
With a wall height of 9 feet 6 inches the required setback on the northern property line is 6 feet 4 inches. The proposed Sleeping Quarters encroaches into the required setback.
A Design Development Option must be applied for and approved before this permit can be approved by Zoning.

A Design Development Option (DDO) must be applied for and approved in order to reduce the setbacks as proposed before this permit can be approved by Zoning.

The below paperwork can be filled out and submitted with the next submission.
DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/2019_ddo_for_setback_and_height_udc.pdf
For more information about the DDO process contact Wyatt Berger at wyatt.berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov
4. COMMENT: If the Sleeping Quarters is to remain detached, a neighbor’s setback waiver may be utilized to reduce the required setback in lieu of the DDO. However, for the Sleeping quarters to remain detached the combined square footage of the one-car garage and sleeping quarter will have to meet the requirements stated in Comment 1.
The neighbor waiver shall be signed by the property owners of Pima County Tax Parcels Number 126-05-0300. The signed neighbor waivers shall be directly pasted on the site plan and shall include the following text:
My name is ______ and I am the owner of the property located at ______. I have reviewed the site plan and I have no objection to the structure being located or construct __ feet from the property line as depicted on the site plan.
Signature: ________
Date: _________

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: revised residential building permit along with a detailed response letter, which states how all Zoning Review Section comments were addressed. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf

If you have any questions about this transmittal, please contact Nathan Herrera at Nathan.Herrera@TucsonAZ.gov or at 520-837-4894
03/05/2024 PDSD Application Completeness Express REVIEW COMPLETED