Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0323-04037
Parcel: 12008648A

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.2

Permit Number - TC-RES-0323-04037
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/04/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/04/2023 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0323-04037 (4848 S LIBERTY AV TUCSON, AZ 85714)

Provided Gas Piping Template is incomplete and piping shown is undersized. Provide an updated Template with the information listed below:

1. Pipe template should show full gas pipe connections to each appliance, lengths of each segment, and size of each segment.
2. Specify Developed length. Measured from gas meter to furthest attached appliance, 2018 IRC G2413.4.1.
3. Specify location of gas leak and repair. What was the extent of the repairs made?
4. Use 2018 IRC Table G2413.4(1) (Metallic Pipe) to calculate correct required pipe sizes. Use Developed length calculated in item 2 above.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
04/04/2023 PDSD Application Completeness Express REVIEW COMPLETED