Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-0323-04032
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/20/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/20/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-0323-04032 (8550 E WRIGHTSTOWN RD TUCSON, AZ 85715) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Code references are to the 2017 National Electrical Code (NEC). 1. The address on the application and the address on the provided plans do not match. Review cannot be complete until correct address and plans are provided. 2. Note on all plans to include Overcurrent protective device and Conductor Sizing calculations, NEC 690, NEC 310.15. Also show the MSP bus calculations that meet the 120% rule, NEC 705.12. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 03/31/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |