Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0323-03764
Parcel: 129010930

Address:
2419 E 19TH ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0323-03764
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/18/2023 Site Zoning APPROVED
04/05/2023 Site Engineering NOT REQUIRED
04/18/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/13/2023 Residential Building REQUIRES RESUBMIT 1. Consolidate pages of construction plans into a single .PDF file as prescribed at the PDSD web site.
2. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38 or R-30 when extended over the wall top plate for additions under 500 SF
03/23/2023 PDSD Application Completeness Express REVIEW COMPLETED