Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0323-03673
Parcel: 124062560

Address:
309 N PARK AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0323-03673
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/12/2023 Site Engineering APPROVED
04/05/2023 Site Zoning APPROVED
04/14/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
04/14/2023 Residential Building REQUIRES RESUBMIT Permit Review TC-RES-0323-03673 (309 N PARK AV TUCSON, AZ 85719)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken.

GENERAL REQUIREMENTS:
The City of Tucson adopted the 2018 International Swimming Pool and Spa Code and 2018 International Residential Code with amendments on 1/1/2019 along with requirements of the Arizona Revised Statute 36-1681. Show the current code reference on the plans.

All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration

SITE PLAN:
1. Show compliance with the pool enclosure barrier requirement by including a continuous 5-foot barrier around the pool, including Self-closing/Self-latching gates that open away from the pool, ARS 36-1681.

PLUMBING PLANS:
1. Notate and specify all piping materials and equipment, P2608.
2. Show gas line size, type and rout/length from gas meter to pool heater. Show burial depth and tracer line, G2415.17.3.
3. Show gas pipe sizes in compliance with connected pipe-length and demand, G2413.3 & Table G2413.4(1) Metallic pipe or Table G2413.4(7) Polyethylene plastic pipe. Provide a gas line isometric or table for showing the BTU demand and length of line to each gas appliance.

ELECTRICAL PLANS:
1. Use Table E3705.5.3 for sizing 15, 20 & 30 AMP branch circuit conductors and protection ratings.
2. Show electrical line from electrical service panel to pool equipment along with wire size, type and burial depth.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
03/21/2023 PDSD Application Completeness REVIEW COMPLETED