| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/12/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/12/2023 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0323-03590 (2231 E MABEL ST TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated plans and calculations with a written response to each of the notated items indicating action taken. 1. OCPD for copper conductor may not exceed 15A for #14, 20A for #12 or 30A for #10 rating required by 2017 NEC 240.4(D)(small conductors). a. #14 AWG for pool pump is undersized. b. #8 AWG for Subpanel is undersized. 2. Show compliance with the pool/Spa barrier from a dwelling by including a UL 2017 listed pool alarm system for doors and windows open to the pool/spa, 2018 ISPSC 305.4.1, Or show Spa equipped with a lockable safety cover complying with ASTM F1346. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 03/17/2023 | Site Engineering | REQUIRES RESUBMIT | Project: TC-RES-0323-03590 Address: 2231 E MABEL ST This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://tdc-online.tucsonaz.gov/#/home NOTE: Documentation of a cost estimate from your contractor will be required if this project involves any reconstruction, repair, rehabilitation, structurally connected addition, or other improvement of an existing structure (including TI’s and solar). Construction of separate builds/new structures does not require a cost estimate to be provided. Instructions: 1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record 2. Locations -> Confirm the location is accurate to the project. Click “Next” 3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next” 4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next” 5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next” 6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next” 7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next” 8. Review and Submit -> Review all information to ensure accuracy. Click “Submit” Contact Scott Haseman at scott.haseman@tucsonaz.gov or Stephen Blood at Stephen.Blood@tucsonaz.gov if you have any questions about the FUP. |
||
| 03/16/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 04/05/2023 | Site Zoning | REVIEW COMPLETED |