| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/24/2023 | Site Landscape | NOT REQUIRED | |||
| 04/12/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/11/2023 | Residential Building | REQUIRES RESUBMIT | PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. Provide a clear and concise construction plan set. Sample drawings are shown as an example: https://www.tucsonaz.gov/pdsd/residential-permits SITE PLAN: 1. Indicate the location and size of buildings, utility meters and lines supporting the alterations, R106.1.1. Include the carport location and size. Show the utility lines requiring upgrade or replacement. STRUCTURAL PLANS: 1. Identify the replaced or repaired items , R106.1.1. 2. Provide a Roof Framing Plan showing the location and size of beams, headers, and rafters for supporting live and dead structural loads, R804. SECTIONS - DETAILS: 1 Show reinforced footing dimensions required for post/beam construction, R403.1.1. 2 Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. ELECTRICAL PLANS: 1. Show any electrical alterations. If you have any questions, please contact: Ken Van Karsen (520) 791-5550 City of Tucson Residential Plan Review |
||
| 04/12/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0323-03526 1527 South Prudence Road – R-1 Carport repair (1st Review) TRANSMITTAL DATE: April 12, 2023 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Submit a site plan that meets the residential plot plan requirements found at this link: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. The residential plot plan requirements are also numbered and listed on the second page of the above link. 2. Clarify whether the carport will be repaired like-for-like or will expand its original footprint or height. If you have any questions about this transmittal, contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 03/16/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 03/17/2023 | Site Engineering | REVIEW COMPLETED |