Permit Number: TC-RES-0323-03520
Parcel: 124070370

Address:
729 E 9TH ST

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1

Permit Number - TC-RES-0323-03520
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/21/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/21/2023 Residential Building REQUIRES RESUBMIT All code references are to 2018 International Residential Code.
PLUMBING Plans:
1. Note and specify all piping materials, P2609.
2. Use Table G2413.4(1) to calculate correct required pipe sizes (Metallic Pipe).
a. Piping is undersized. Requires 1 ¼” from meter to WH, and ¾” from WH to furnace.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
03/13/2023 PDSD Application Completeness Express REVIEW COMPLETED