Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - TC-RES-0323-03513
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/13/2023 | Residential Building | APPROVED | |||
| 06/13/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/23/2023 | Site Engineering | REQUIRES RESUBMIT | 1. Resubmit with most recently approved flood vented plans. Lianne Evans lianne.evans@tucsonaz.gov |
||
| 05/25/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0323-03513 1818 N DRAGOON ST / R-2 Garage Addition (2nd Review) TRANSMITTAL DATE: May 25, 2023 Provide a drawing of the proposed garage from a bird’s eye view on the site plan. 1. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height of 9’-6” the required perimeter yard setback from the proposed garage to the east property line is 6’-4”, proposed setback is 6’-0”. Per UDC Article 6.6.2.D An accessory structure that exceeds the allowable height of a wall within a perimeter yard and is detached from a principal structure shall comply with the perimeter yard width standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjoining or, when separated by an alley, adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s): My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ 2. There appears to be a discrepancy on the elevations/sections on sheet A104. East Elevation shows a 9’-6” dimension from design grade to top of wall, section A show a 9’-6” dimension from finished floor to ceiling, this is not possible, correct the dimensions so that setback requirements can be verified. 3. Per UDC Article 6.6.3.D Accessory structures, except for accessory dwelling units, shall not exceed 12 feet in height, unless attached to a principal structure. If attached to the principal structure, maximum height permitted shall be the same as for the principal structure. Per UDC Article 6.4.4.A Measurement of Building Height, Building height is the vertical distance measured from the design grade elevation to the middle (between the eave and ridge) of a pitched roof. Provide a height dimension from design grade to the midpoint of the pitched roof. If the proposed garage exceeds the allowed 12’ height a Board of Adjustment for Variance will be required. Board of Adjustment application and requirements can be found at: https://www.tucsonaz.gov/pdsd/zoning-administration-applications. If you have questions about the Board of Adjustment application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 05/23/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |