Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0323-03383
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/14/2023 | Site Engineering | NOT REQUIRED | |||
| 03/14/2023 | Site Landscape | NOT REQUIRED | |||
| 04/06/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/06/2023 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0323-03383 (9330 E SIERRA AV TUCSON, AZ 85710) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. SITE PLAN: 1. Indicate the location and size of buildings, utility meters and lines, R106.1.1. Show the utility lines. Elevation Views: 2. Show TEP service wires meet 2017 NEC Article 230 overhead clearance requirements, (A) Over building roofs – Conductors shall have a vertical clearance of not less than 8 feet above the roof surface. The vertical clearance above the roof level shall be maintained for a distance of not less than 3 feet in all directions from the edge of the roof. (B) Over residential property and driveways on the property, not subject to truck traffic – 12 feet. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 03/31/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-RES-0323-03383 9330 E Sierra Av. – SR Two (2) Detached Accessory Structures (1st Review) TRANSMITTAL DATE: March 31, 2023 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the SR zone (UDC 4.7.4). A single family residence is a permitted use in the zone, (Table 4.8-1). 1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf, for parcel 122-05-0830 only. This plot plan shall include but not limited to: a. Legal description. b. Owners name. c. The property dimensions shown are not correct. Review final plat Harrison Estates found at: https://www.tucsonaz.gov/apps/maps-and-records/subdivisions/details/1184, and provide the correct property dimensions. d. Indicate the zoning of the property and all adjacent properties. 2. Per UDC Article 6.6.3.E The total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure. Accessory structures less than 200 square feet gfa and accessory dwelling units are exempt from this requirement. Provide a calculation on the plot plan that clearly demonstrates that the detached garage and storage container square footage does not exceed 50% of the dwelling square footage. 3. Based on aerial photos there are several small structures shown on the site that are not shown on the plan. Show all structures that are on the site on the plot plan. If these structures are to be removed show them as such. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov |
||
| 03/09/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |