Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0323-03346
Parcel: 103216160

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SOLAR v.1

Permit Number - TC-RES-0323-03346
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/04/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
01/04/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0323-03346 (2137 W FROSTWOOD LN TUCSON, AZ 85745)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC).

1. Provide updated module layouts and Uplift calculations, PV-01, PV-02, R301.1, R324.4. Show the location of the new modules, racking system, anchor points and MI.
2. Add the following note to the plans, “Tesla Gateway 2 shall be setup in compliance with 2020 NEC 705.13 and UL1741, Power Control System to protect the MSP bus.” PV-04.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
12/27/2023 PDSD Application Completeness REVIEW COMPLETED