Permit Review Detail
Review Status: Approved
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-0323-03214
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Approved
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/16/2023 | Bldg Permits - Post Review Express | REVIEW COMPLETED | |||
| 03/16/2023 | Light Residential Building Review (OIP) | REVIEW COMPLETED | Approved with comments: • Provide complete roof framing information for determining load carrying capacity for the roof structure. Show all load bearing locations. Demonstrate the ability for supporting the existing and additional dead load, or provide and engineer’s calculation, design and seal for verifying the truss load carrying capacity. • Provide a lag-bolt connection up-lift calculation demonstrating the wind load supporting capability, R301.1. An IRC PV roof uplift calculator is available on Pima County’s website. https://webcms.pima.gov/cms/One.aspx?pageId=62064 • When applying for a permit to place new equipment on existing code-compliant roofs, an allowance shall be provided for equipment weighing a maximum of 4 psf and load per attachment point of 40lbs or less. https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Development%20Services/Building/Equipment%20on%20roofs%20.pdf |
||
| 03/09/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |