Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT SIMPLE REVIEW v.1
Permit Number - TC-RES-0226-01037
Review Name: RESIDENTIAL ADD/ALT SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/13/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/02/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-RES-0226-01037 Location: 912 S COLGATE DR Review Date: 3/2/2026 Site Engineering Comments: 1. This property resides within a FEMA XS100 Floodplain and will require a floodplain use permit with elevation certificate for flood venting. 2. This will require the submission of a Floodplain use permit with elevation certificate. Please start a new FPU at our permit application web page: https://tdc-online.tucsonaz.gov/#/home The FPU permit is a separate permit that can be submitted within the sub-records tab of this building permit on TDC online. 3. For the shed, flood venting will be required according to Tucson Code PART II Chapter 26, Section 26-11.2.(8). A minimum of two openings will be required. The vents will have a total net area of not less than one square inch for every square foot of enclosed area. Openings may be equipped with screens, louvers, valves, or other coverings or devices if they permit the automatic entry and exit of floodwater. 4. For resubmission of the residential building permit and submission of the flood plain use permit, have the flood vents and a detail shown on the construction plans. Have the detail include dimensions of vents as well as height above grade. 5. Site engineering is unable to approve this permit until the Floodplain Use Permit has been issued. Corey Hines Corey.Hines@TucsonAZ.gov |
||
| 03/13/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-RES-0226-01037 912 S Colgate Dr., Tucson, AZ 85710 Shed (1st Review) TRANSMITTAL DATE: 03/13/2026 This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. Site Planning is unable to approve the site plan until a Floodplain Permit Use permit is issued. Once the FPU is approved, please upload a copy of the approval with the required materials for the next review. 2. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. The City of Tucson Unified Development Code may be accessed at this site: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-1 Recent amendments to the UDC may be found here: https://tucsonaz.hylandcloud.com/221agendaonline/Documents/ViewDocument/ORDINANCE%2012219.pdf?meetingId=1890&documentType=Agenda&itemId=77068&publishId=189435&isSection=false If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov |
||
| 03/02/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |