Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0226-00988
Parcel: 135060560

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0226-00988
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/27/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/27/2026 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT If you have any questions regarding these Residential Building Safety comments, I can be reach at jorge.ruiz@tucsonaz.gov

Repair type not applicable.

1. P3011.2 (IRC 2024) -The relining of existing building sewer piping and building drainage piping shall be limited to gravity drainage piping 4 inches (102mm) in diameter and larger. The relined piping shall be of the same nominal size as the existing piping.
02/26/2026 PDSD Application Completeness Express REVIEW COMPLETED