Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0226-00985
Parcel: 140170940

Address:
1335 E NEVADA DR

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0226-00985
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/26/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/26/2026 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT For any questions, please email: PDSD-Residential@tucsonaz.gov

Please resubmit addressing the following comments:

1. Show demand for all gas appliances. Modifications to the gas piping requires the submission of a gas pipeline template (or equivalent) to determine pipe sizing, G2401.1, G2413.1, R301.1
2) Include pipe size, type (Black Iron, Poly) and length. G2401.1, G2413.1, R301.1:
3) Size the pipe based on the length from the meter to the farthest attached appliance and max total demand of all attached appliances using Table G2413.4(1) (Metallic Pipe), Table G2413.4(7) Polyethylene Plastic Pipe. Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1.

See:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_handout_2018_irc_2019.2.4.pdf
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_piping_template_060324.pdf
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_piping_sample_060324.pdf
02/26/2026 PDSD Application Completeness Express REVIEW COMPLETED