| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/04/2026 | Residential Zoning | APPROVED | |||
| 05/06/2026 | Restamp Residential Building | APPROVED | |||
| 05/06/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/06/2026 | Restamp Residential Engineering | REQUIRES RESUBMIT | Permit Activity Number: TC-RES-0226-00933 (1st Review) Project: additional square footage to primary residence, extend carport, new porch Location: 2558 E MONTE VISTA DR Review Date: 5/6/2026 Reviewer: Marco Contreras – Engineering Associate - Site Engineering Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter review time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. Provide a response letter addressing each comment with location of change on the plans. Submit the separate response letter and plan set files. Site Engineering Review Comments: 1. There appears to have been an error done by Site Engineering regarding the review and approval of this residential building permit TC-RES-0226-00933 Refer below for the missing items regarding this residential building permit. 2. This property located at 2558 E MONTE VISTA DR is located entirely within a designated City of Tucson Flood floodplain associated with the Treat Ave wash. As this is a residential building permit for a RES addition, carport extension and new porch to a PRE-FIRM (1947) structure located within a designated flood hazard/floodplain, it will require the submission of a separate floodplain use (FPU) permit application. The floodplain use (FPU) permit is an entirely separate permit that can be submitted within the sub-records of this residential permit through TDC Online. a. The flood plain use permit will involve the substantial improvement/substantial damage (SI/SD) process with the submission of a cost estimate from the registered contractor. The cost estimate must be submitted on official company/contractor letterhead and shall itemize all costs associated with the proposed scope of work, broken down into separate line items including, but not limited to: ALL MUST BE SEPERATED or Resubmission will be required i. Labor (all trades) ii. Materials and Equipment iii. Overhead and Profit iv. Warranties, Permits, and Fees b. The cost estimate must reflect the full market value cost to complete the proposed work. Estimates that reflect only partial scopes, discounted rates, or owner-supplied labor must still account for the fair market value of all work performed. NOTE: Lease agreements, payment plans, financing agreements, or any other financial instrument will not be accepted as a substitute for a bona fide contractor cost estimate. If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov |
||
| 04/22/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |