Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-0226-00792
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/17/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/17/2026 | Light Residential Building Review (OIP) Express | REQUIRES RESUBMIT | Panel upgrade comments Please show or describe how Whole home surge protection will be installed in the panel and re submit. Code references from the 2024 IRC below. E3606.5 Surge protection: all services supplying dwelling units shall be provided with a surge-protective device (SPD) installed in accordance with Sections E3606.5.1 through E3606.5.3. E3606.5.1 Location: the SPD shall be an integral part of the service equipment or shall be located immediately adjacent, if not located at each next-level distribution equipment downstream toward the load. E3606.5.2 Type: the SPD shall be a Type 1 or Type 2 SPD. E3606.5.3 Replacement: Where service equipment is replaced, all of the requirements of this section shall apply. |
||
| 02/17/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |