Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.2
Permit Number - TC-RES-0226-00769
Review Name: RESIDENTIAL ADD/ALT v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/03/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/03/2026 | Residential Building - Standard | REQUIRES RESUBMIT | The previous building safety comments were not fully addressed. The submitted drawings show the cover only extending to the edges of the driveway however, map images show the cover extending to the property boundary. Please provide sizing of the beam supporting the cover, as well as the span between posts. Provide mounting details indicating how the beam is secured to the posts, as well as the hardware used to mount the posts to the slab. Indicate if there are footings for the posts. Provide the size and spacing of the rafters supporting the metal cover and indicate whether any sheathing has been used. Should you have any questions about these comments, I can be reached at ian.gillaspie@tucsonaz.gov. |
||
| 03/27/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Erick Bieber Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0226-00769 – Residential Building 1635 S Shannon Rd, Tucson, AZ 85713 Residential Addition/Alteration (1st Review) TRANSMITTAL DATE March 27th, 2026 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. (Comment) The site plan provided is not sufficient. Please meet the following comments given in the previous review, and refer to the following link for site plan examples: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Site-Plan-Examples a. Draw, label and dimension everything that exists on the property to a scalable drawing graphic (examples include the principal residence, porches, breezeways, sidewalks, driveways, parking spots, walls, fences, ramada, shed, carport, shade sail, cistern, pool, guest house, sleeping quarters, accessory dwelling unit) and provide dimensions of any structure as it relates to nearby structures and property lines and provide the heights (measured from above finish grade to top of wall, etc.) of those structures that run parallel-perpendicular to any nearby adjacent property lines. Provide heights at various locations along the fence/wall if applicable. b. Refer to Pima County’s website https://gis.pima.gov/maps/detail.cfm?&parcel=11803216A to locate and provide the parcel number, legal description, subdivision name, book and page numbers, township-section and range, sequence number on the plot plan. c. Draw, label and dimension all property lines, (provide property line lengths) and any easements to be reflective of information on Pima County’s website. Refer to Pima County’s website https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=24062 . The math of the property line lengths will produce the total parcel square footage. Be aware that some easements may require referring to the title report of the property (procure at title company if not already in possession. For example, this is especially significant in avoiding building in a utility easement where the provider may need regular access to service. Any need to build within the easement would then require written approval from the utility provider within that easement. d. A lot coverage calculation table was not provided. Per UDC Article 6.4.3.C.1.a roofed areas, porches, open on at least one side are NOT included in the calculation and per UDC Article 6.4.3.B.3.b Vehicular use areas, measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved are included in the lot coverage. Calculate (measure) square footage of every enclosed (NOT open structures like a porch, ramada, carport) structure on site and all vehicular use area (driveway, parking, turnaround, backup) and input into lot coverage calculation table. A carport would be calculated under vehicular use area. These separate ‘category numbers’ are added together and divided by the total parcel square footage to produce the lot coverage percentage that demonstrates compliance (or not). e. Draw, label and dimension the principal residence graphic to be representative of that via Pima County’s website (property record card) https://www.asr.pima.gov/ParcelData/prc/11803/216A.pdf . Include any unpermitted additions, modifications and label. f. Provide R-1 zoning labels on all four sides of this parcel (including this parcel). g. Provide missing site plan scale, corresponding graphic scale and north arrow. h. If the drawing provided is done by a professional, include the drafter-designer-consultant name, address, license number and contact information on the title block of every sheet. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov |
||
| 03/16/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |