Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0226-00712
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/19/2026 | Residential Engineering | NOT REQUIRED | |||
| 03/09/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/09/2026 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0226-00712 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2024 International Residential Code and 2018 International Energy Conservation Code. The 2024 International Energy Conservation Code takes effect July 1st. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2024 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections. Provide a separate response letter addressing each comment with location of change on the plans. SITE PLAN: 1. Show the location utility meters and water, electric and sewer lines from property line to building, R106.1.1. Identify the utility lines requiring upgrade or replacement. PLANS: 1. Provide a minimum 6 mil polyethylene vapor retarder with joints lapped not less than 6 inches between the concrete floor slab and the base course or the prepared subgrade where a base course does not exist, R506.3.3. SECTIONS - DETAILS: 1. Show the infill garage door opening detail with sheathing and sill clearance 4” above grade or 2” above paved areas, R703.7.2.1. This may require a concrete stem. MECHANICAL PLANS: 1. Provide makeup air of not less than 100 square inches where a clothes dryer is placed in a closet, M1502.6.1. ELECTRICAL PLANS: 1. Provide GFCI protection for appliance receptacle outlets, E3902.12. Include: 1. Drinking water coolers 2. High pressure spray washing machines 3. Sump pumps 4. Dishwashers 5. Electric ranges 6. Wall-mounted ovens 7. Counter-mounted cooking units 8. Clothes dryers 9. Microwave ovens 2. Interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. Add notation to plans. OUTDOOR LIGHTING CODE 1. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
||
| 02/27/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Erick Bieber Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0226-00712 – Residential Building 289 W Teton St, Tucson, AZ 85756 Residential Addition/Alteration (1st Review) TRANSMITTAL DATE: February 27th, 2026 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. (Comment) Please indicate all structures on the site plan. Aerial imagery indicates an accessory structure in the rear yard that is not drawn on the site plan. 2. (Comment) Zoning cannot locate permits for the accessory structure located in the rear yard. A permit will need to be submitted for the accessory structure before this permit can be approved. 3. (Comment) The 20ft setback noted on the site plan is incorrect. It appears to have been measured from the curb, when the front street setback is measured from the property line. 4. (Comment) Per UDC Section 6.4.5.C.b, where a lot abuts more than one street, the owner chooses which street lot line is the front lot line. From other than the front lot line, the street perimeter yard is ten feet, as measured from the street property line. Currently, the front street setback is being measured from W Teton St, whereas S San Fernando Rd may be the more appropriate front street. The average setback dimension of the proposed addition is approximately 10.5’, which would meet the 10’ side street setback requirement, but not the 20’ front street setback requirement. Please indicate which streets you consider to be the front street and the side street. 5. (Comment) Please dimension all vehicular use areas and add the total vehicular use area square footage to the lot area calculation. This includes driveways, parking areas, or any space used for maneuvering vehicles. 6. (Comment) Per UDC Article 6.4.3.C.1.a Roofed areas, porches, open on at least one side are not included in the calculation. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov |
||
| 02/17/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |