Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0226-00671
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/19/2026 | Residential Zoning | APPROVED | |||
| 03/09/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/09/2026 | Residential Building - Standard | REQUIRES RESUBMIT | Please address the following comments and resubmit. 1. Provide a foundation plan. IRC, R301.1. R403.1.6. 2. Show ignition source appliances installed in garages with platforms at least 18” above the floor, M1307.3, G2408.2 & P2801.6. 3. Show a carbon monoxide detector installation outside of bedroom doors, R315.3. This is required as permitted work is done within existing dwellings having attached garages or having fuel-fired appliances 4. Show impact protection for appliances located in the garage, M1307.3.1. 5. Garage Branch Circuit: a separate (dedicated) GFCI 20-amp branch circuit required for receptacles in an attached garage and detached garages with service, E3703.5. |
||
| 02/12/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |