Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0226-00671
Parcel: 133211170

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0226-00671
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/19/2026 Residential Zoning APPROVED
03/09/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/09/2026 Residential Building - Standard REQUIRES RESUBMIT Please address the following comments and resubmit.
1. Provide a foundation plan. IRC, R301.1. R403.1.6.
2. Show ignition source appliances installed in garages with platforms at least 18” above the floor, M1307.3, G2408.2 & P2801.6.
3. Show a carbon monoxide detector installation outside of bedroom doors, R315.3. This is required as permitted work is done within existing dwellings having attached garages or having fuel-fired appliances
4. Show impact protection for appliances located in the garage, M1307.3.1.
5. Garage Branch Circuit: a separate (dedicated) GFCI 20-amp branch circuit required for receptacles in an attached garage and detached garages with service, E3703.5.
02/12/2026 PDSD Application Completeness Express REVIEW COMPLETED