Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0226-00651
Parcel: 133070730

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.3

Permit Number - TC-RES-0226-00651
Review Name: RESIDENTIAL ADD/ALT v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/02/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/02/2026 Restamp Residential Building REQUIRES RESUBMIT A roof projection may not extend closer than 24” to the adjoining (neighboring) property line. Any part of a roof projection extending into the 3-foot fire separation distance from the property line requires not less than one-hour fire-resistive construction on the underside, R302.1 (City of Tucson Amended).

Show the (Ramada B north side) structure with one-hour fire-resistive wall (fire spread barrier) parallel with the adjoining (neighboring) property line in compliance with IBC Table 721.1(2) or provide a clear 24" fire separation distance between the property line and the structure.

Provide a separate response letter addressing the comment. Submit the updated construction plans in a separate file from the letter.
04/01/2026 PDSD Application Completeness Express REVIEW COMPLETED