Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.3
Permit Number - TC-RES-0226-00651
Review Name: RESIDENTIAL ADD/ALT v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/02/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/02/2026 | Restamp Residential Building | REQUIRES RESUBMIT | A roof projection may not extend closer than 24” to the adjoining (neighboring) property line. Any part of a roof projection extending into the 3-foot fire separation distance from the property line requires not less than one-hour fire-resistive construction on the underside, R302.1 (City of Tucson Amended). Show the (Ramada B north side) structure with one-hour fire-resistive wall (fire spread barrier) parallel with the adjoining (neighboring) property line in compliance with IBC Table 721.1(2) or provide a clear 24" fire separation distance between the property line and the structure. Provide a separate response letter addressing the comment. Submit the updated construction plans in a separate file from the letter. |
||
| 04/01/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |