Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.4
Permit Number - TC-RES-0226-00651
Review Name: RESIDENTIAL ADD/ALT v.4
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/14/2026 | Residential Building - Standard | APPROVED | |||
| 04/16/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/16/2026 | Restamp Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Jeffrey W. Cassidy, Planner Planning & Development Services Department – Current Zoning Review Section PROJECT: TC-RES-0226-00651– Residential Building – Install 2 Freestanding Ramada's 2110 N SARNOFF DR TUCSON, AZ 85715 (RX-2 Zoning) Site Plan Review – 3rd Review TRANSMITTAL DATE: April 16, 2026 This site is in the RX-2 Residence Zone (UDC 4.7.7). A single-family detached residence is a permitted use in this zone (Table 4.8-7). The City's Unified Development Code (UDC) (Section 1.4.1.C) establishes that before the City issues any approvals or permits; we must confirm that a site complies with UDC standards. Therefore, as part of permit reviews, we review a site's permit history and compare it to aerial photography to confirm that unpermitted work has not occurred. In many cases, this does mean that a homeowner must apply for permits for unpermitted work before we can approve any new work on that site. Plan review for the above referenced two ramadas has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. 1. COMMENT: The site plan provided is incomplete. Provide a site plan that meets the requirements show in the plot plan example at the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/plan-samples/basic-site-plan_feb2026.pdf Specifically: A. Draw, label and dimension everything that exists on the property to a scalable drawing graphic (examples include the principal residence, porches, breezeways, sidewalks, driveways, parking spots, walls, fences, ramada, shed, carport, shade sail, cistern, pool, guest house, sleeping quarters, accessory dwelling unit) and provide dimensions of any structure as it relates to nearby structures and property lines and provide the heights (measured from above finish grade to top of wall, etc.) of those structures that run parallel-perpendicular to any nearby adjacent property lines. Provide heights at various locations along the fence/wall if applicable. Draw (with dashed lines) and label the two existing sheds in the northeast corner of the property to be removed and note that action accordingly (to accommodate the two new ramadas). Label the sheds and provide the size of each structure. B. Provide the missing 135’-0” property line dimension along the south property line and replace the “1 label” at the southwest corner with a 39.27’ label. C. The neighbor to the east needs to update the distance to 2’-0” as opposed to the 32’-0” they currently approved. Additionally, they need their language to endorse BOTH ramadas. D. The alley (not the center of the alley) is 16’-0” wide (as opposed to the 32’-0” dimension currently shown. The centerline of the alley would be 8’-0 (as opposed to the 16’-0” shown). Update both dimensions accordingly. E. Provide RX-2 zoning labels on all four sides of this parcel (including this parcel). F. The 20’-0” dimension south of the carport is incorrect. Be sure the dimension is taken from the property line and not the street edge of curb (in the City right of Way). 2. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: 1. Corrected building permit 2. Provide a detailed response letter (clarification narrative) with your submittal that clearly shows how you have addressed all Zoning comments. 3. Resubmit ALL documents associated with this permit (all drawings in sheet index) To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code |
||
| 04/10/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |