Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0226-00573
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/05/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/05/2026 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0226-00573 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2024 International Residential Code and 2018 International Energy Conservation Code. The 2024 International Energy Conservation Code takes effect July 1st. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2024 IRC code compliance. Place the 2024 I-Code reference code on sheet A1.0 rather than a code that was in effect in the past. Plans must show compliance with the adopted code at the time of permit application submittal. Provide a separate response letter addressing each comment with location of change on the plans. SECTIONS - DETAILS: 1. Provide an engineer’s calculation, design and seal for masonry partition and screen walls exceeding 7’ in height above grade detail #1 on A2.0, R301.1.3. Calculation for determining the required vertical structural steel. 2. Individual dwelling units require separation with a 1-hour fire-resistance rated assembly without openings extended from floor to roof, R302.3. Provide a detail or notation (keynote #5 sheet A2.0) showing compliance with 703.3 of the IBC. ELECTRICAL PLANS: 1. Show a smoke alarm in the bedroom and outside the doorway in the immediate vicinity with an electrical circuit, R314.2.2. OUTDOOR LIGHTING CODE 1. Update the Outdoor Lighting Calculation showing the area as E3, 401. If you have any questions, please contact: Kenneth.VanKarsen@tucsonaz.gov City of Tucson Residential Building Safety |
||
| 02/27/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Jeffrey W. Cassidy, Planner Planning & Development Services Department – Current Zoning Review Section PROJECT: TC-RES-0226-00573 - Residential Building – Duplex to accessory dwelling unit (ADU) conversion 1715 N HIGHLAND AV TUCSON, AZ 85719 (R-2 Zoning) Land Split Building Solar Demolition Site Plan Review – 1st Review TRANSMITTAL DATE: February 27, 2026 This site is in the R-2 Residence Zone (UDC 4.7.9). A duplex is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10 This site is in the R-2 Residence Zone (UDC 4.7.9). An accessory dwelling unit (ADU) is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, 8, & 9 and 6.6.3. Plan review for the above referenced duplex to accessory dwelling unit (ADU) conversion has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. 1. COMMENT: Scope will need some clarification as to the motivation behind this conversion as well as provide insight as to the four ramifications listed below. 1a. The conversion will be reviewed as a new project and doing so will incur not only impact fees for each accessory dwelling unit (ADU). 1b. Per Ordinance 12219, all new accessory dwelling units (and single family residences (TC-RES-1025-05252)) are required to meet new landscape standards. As currently presented, both permits would require landscaping under the new Ordinance. 1c. Accessory Dwelling Units are permitted as an accessory to an existing principal residence. This is not the case in this instance and isn’t necessary if you choose to maintain this as a duplex. However, concurrent permits are allowed but the new principal residence (TC-RES-1025-05252) needs to be permitted prior to this permit being approved. 1d. Detached ADU’s are not permitted in the front yard (E Elm St) proud of a principal residence location but can be if they are attached to the principal residence. It appears both permits indicate a form of attachment, but Zoning wanted to clarify and provide the applicant to confirm this in writing. Confirm that you wish to continue with this permit as is, change to Middle Housing (combine both permits) or withdraw this one and keep as a duplex. 2. COMMENT: Should you continue down the path of separate permits ADU conversion: TC-RES-0226-00573 and new SFR: TC-RES-1025-05252 be sure to keep the scope clean from each other’s permit. You are welcome to reference ‘the other related scope’ with its permit number but be sure the specific content to each scopes permit is separate from each other moving forward. Currently, the SFR permit indicates the inclusion of the ADU’s as though they were intended to be part of that permit. 3. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: 1. Corrected building permit 2. Provide a detailed response letter (clarification narrative) with your submittal that clearly shows how you have addressed all Zoning comments. 3. Resubmit ALL documents associated with this permit (all drawings in sheet index) To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code |
||
| 02/11/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |