Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0226-00537
Parcel: 128061280

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0226-00537
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/26/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/06/2026 Addressing Validation REQUIRES RESUBMIT If you have questions, please contact PDSD-Residential@tucsonaz.gov

Please include full property address on site plan and resubmit after other reviews are complete.

Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf
02/26/2026 Residential Building - Standard REQUIRES RESUBMIT Clarify if the proposal is for a detached addition to the existing dwelling (without kitchen) or a new dwelling with kitchen. A living unit with kitchen is considered a dwelling ADU and will require an impact fee payment when the plans are approved.

A permit requires the correct application type. Request the cancellation of this application for an addition/alteration permit and apply for a new dwelling permit. This addition/alteration application may continue if the cooking appliance is removed.

Provide a complete construction plan set showing 2024 IRC compliance.
02/10/2026 Residential Engineering REQUIRES RESUBMIT Permit: TC-RES-0226-00537
Location: 841 S VAN BUREN AV
Review Date: 2/10/2025
Site Engineering Comments:
1. This site resides within FEMA Zone AE floodplain and will require the submission and approval of a floodplain use (FPU) permit with elevation certificate. The FPU permit is a separate permit that can be submitted within the "sub-records" tab of this associated building permit through TDC online.
2. The FPU permit will require an elevation certificate to be completed by a registered land surveyor with intermediate and final submissions.
3. Provide a site plan detailing the location of the new proposed structure. The estimated base flood elevation is 2584.9ft NAVD88 and estimated required finished floor elevation of the structure is 2585.9ft NAVD88. Subject to change depending on the location of the structure.
4. A grading plan is required. The grading plan is a separate permit called a development package and must be applied for through TDC online.
5. The grading plan shall include drainage patterns and any proposed grading (i.e. spot elevations, cut/fill quantities, area of disturbance, grading profile. top/bottom of slope).
6. Per the City of Tucson Inclusive Home Design Ordinance (https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf, all new dwellings have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway (or apron), sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402-404 of the ADA Accessibility Standards (https://www.access-board.gov/ada/chapter/ch04/). See TSM 7-01.4.3 for specifications, including the minimum 4ft-width, slope and composition materials.
7. Final Residential Engineering approval for permit TC-RES-0226-00537 requires resubmission of updated plans matching approved FPU and DP permit.
Corey Hines
Corey.Hines@TucsonAZ.gov
02/13/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Jeffrey W. Cassidy, Planner
Planning & Development Services Department – Current Zoning Review Section

PROJECT: TC-RES-0226-00537 – Residential Building – Build a Casita in back yard of residence
841 S VAN BUREN AV TUCSON, AZ 85711 (R-1 Zoning)
Site Plan Review – 1st Review

TRANSMITTAL DATE: February 13, 2026

This site is in the R-1 Residence Zone (UDC 4.7.8). An accessory dwelling unit is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, 8, & 9 and 6.6.3.

The City's Unified Development Code (UDC) (Section 1.4.1.C) establishes that before the City issues any approvals or permits; we must confirm that a site complies with UDC standards. Therefore, as part of permit reviews, we review a site's permit history and compare it to aerial photography to confirm that unpermitted work has not occurred. In many cases, this does mean that a homeowner must apply for permits for unpermitted work before we can approve any new work on that site.

Plan review for the above referenced accessory dwelling unit (ADU) has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

1. COMMENT: Refer to Residential Engineering reviewer comments 1 thru 7.

Building permits can be submitted and reviewed concurrently with the development package but the building plans (for this permit) cannot be approved by zoning until the development package is approved, and the building plans are reviewed for consistency.

Development Package Submittal Requirements: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-8753

2. COMMENT: No site plan was provided.

Provide a site plan that meets the requirements show in the plot plan example at the following link:

https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/plan-samples/full-site-plan_feb2026.pdf

Specifically:

A. Draw, label and dimension everything that exists on the property to a scalable drawing graphic (examples include the principal residence, porches, breezeways, sidewalks, driveways, parking spots, walls, fences, ramada, shed, carport, shade sail, cistern, pool, guest house, sleeping quarters, accessory dwelling unit) and provide dimensions of any structure as it relates to nearby structures and property lines and provide the heights (measured from above finish grade to top of wall, etc.) of those structures that run parallel-perpendicular to any nearby adjacent property lines. Provide heights at various locations along the fence/wall if applicable.

B. Draw, label and dimension all setbacks. Setbacks for side and rear property lines are 5’-0” flanking the north, south, and east, property lines. The front yard setback is 20’-0” (west property line).

C. Refer to Pima County’s website https://gis.pima.gov/maps/detail.cfm?&parcel=128061280 to locate and provide the parcel number, legal description, subdivision name, book and page numbers, township-section and range, sequence number on the plot plan.

D. Draw, label and dimension all property lines, (provide property line lengths) and easements reflective of the information on Pima County’s website. Refer to Pima County’s website https://maps-and-records.tucsonaz.gov/subdivisions/details/1211 and https://www.asr.pima.gov/ParcelData/Map/Arm/MP08/08088_02.pdf . The math of the property line lengths will produce the total parcel square footage. Be aware that some easements may require referring to the title report of the property (procure at title company if not already in possession. For example, this is especially significant in avoiding building in a utility easement where the provider may need regular access to service. Any need to build within the easement would then require written approval from the utility provider within that easement.

E. A lot coverage calculation table was not provided. Per UDC Article 6.4.3.C.1.a roofed areas, porches, open on at least one side are NOT included in the calculation and per UDC Article 6.4.3.B.3.b Vehicular use areas, measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved are included in the lot coverage.

Calculate (measure) square footage of every enclosed (NOT open structures like a porch, ramada, carport) structure on site and all vehicular use area (driveway, parking, turnaround, backup) and input into lot coverage calculation table. A carport would be calculated under vehicular use area. These separate ‘category numbers’ are added together and divided by the total parcel square footage to produce the lot coverage percentage that demonstrates compliance (or not).

F. Draw and label S Van Buren Av.

G. Provide R-1 zoning labels on all four sides of this parcel (including this parcel).

H. Provide missing site plan scale, corresponding graphic scale and north arrow.

3. COMMENT: As part of the passing of Ordinance 12219 this past December of 2025, the following landscaping is required for all new single family residential, middle housing development, and accessory dwelling units, as of January 01, 2026 per UDC 7.6.10.

A. One canopy tree is required for every 1,000 square feet of gross floor area of the development project.

B. Vegetative groundcover is required within the front yard setback per the calculation below.

(X Linear feet of Street Frontage) – (Y curb cut width) x (5 Foot Depth) = Z Square Feet of required vegetative groundcover.

C. Plants must be low to very low water use with a hardiness rating of 15 degrees
Fahrenheit or lower and non-invasive. Options are listed in Section 5-02.5.0 of
the Technical Standards Manual. Exceptions to these criteria or plants that are
not listed in Section 5-02.5.0 of the Technical Standards Manual, may be
approved by the PDSD Landscape Architect.

D. Required landscaping must be located as follows:

1. A minimum of fifty percent of the required canopy trees must be located within
the front yard setback area.

a. Exception: If site constraints prevent new tree placement in a front yard,
five shrubs may be substituted per required tree. Required trees must still
be placed elsewhere on the site. Shrubs used as a substitute plant material for the required tree shall range from three feet in height by three feet in width, or larger. Shrubs must follow the relevant spacings from utility lines in section 5-01.5.11of the Technical Standards Manual but can be planted one radius of their mature width from foundations, enclosed sidewalks, sidewalks, and curbs.

b. Exception: The tree required for an accessory dwelling unit may be placed anywhere on site.

2. Trees may be planted at varying distances apart.

3. Required landscaping is not restricted to the first 10 feet onto the property from the existing or future right-of-way line.

4. Newly planted trees must be placed at a minimum distance from existing or proposed City of Tucson-owned or private utility-owned lines, as found in section 5-01.5.11 of the Technical Standards Manual. Tree plantings are not permitted in El Paso Gas Easements or under overhead power lines.

5. Trees shall be placed a minimum of ten feet from the center of the tree trunk to any enclosed structure.

6. Trees shall be placed a minimum of five feet from the back of the sidewalk or
curb. If this standard cannot be met, then root barriers are required and must be
illustrated on the submitted construction plans.

7. Trees must be planted in a six-to-nine-inch depressed planting area of at least
50 square feet (four-foot radius, or alternatives as proposed) and at least ten feet
away from a building foundation.

8. Existing, established trees on property, at least 4 inches trunk diameter at chest height, located at least ten feet from the foundation or with an unobstructed dripline at maturity, shall count toward this requirement. The root systems of existing trees used for this requirement must be protected from soil compaction during construction using perimeter protective fencing around the dripline. Established trees are not required to have a depressed planting area. Existing shrubs and vegetative groundcover may also be used toward the required landscaping.

C. Vegetation shall be established, maintained, and sustained throughout its life in support of the City’s tree count, climate, and walkability goals. One of the following two options may be used:

1. Drip or bubbler irrigation with backflow protection. A simple irrigation system can be part of the domestic water supply for the residence.

2. Alternate methods, such as rainwater harvesting, hand watering, and greywater systems, as proposed by the property owner and approved by the PDSD Landscape Architect.

D. Proposed landscaping and related items can be included in a residential plot plan; a
Landscape Plan is not required.

4. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:

1. Corrected building permit

2. Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments.

3. Resubmit ALL documents associated with this permit

To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home

Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf

If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code
02/06/2026 PDSD Application Completeness Express REVIEW COMPLETED