Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0225-01105
Parcel: 124090070

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0225-01105
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/29/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/12/2025 Addressing Validation REQUIRES RESUBMIT Please provide the unit number on all pages of the construction plans.

Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf

For questions: Building_Official@tucsonaz.gov
04/29/2025 Design Review - Standard REQUIRES RESUBMIT Plans show work visible from the Right-of-Way, Neighborhood Preservation Zone design review is required.

Please refer to the instructions at the following link:
https://www.tucsonaz.gov/files/sharedassets/public/v/3/pdsd/documents/submission-documents/special_districts_application_instructions_7.18.23.pdf
04/03/2025 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0225-01105 unit A & TC-RES-0425-01702 unit B
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

GENERAL COMMENTS :

1. Show the description on sheet g1.0 as Renovate SFR into Duplex.
2. Remove the prefab roof trusses as a deferred submittal from sheet g1.1.
3. Unit “B” requires an impact fee for the new dwelling at the time of permit payment.

PLANS:

1. Show compliance with R310 providing egress from bedrooms with minimum net clear opening of 24” height. Change the 2640 SH bedroom windows to 2646 SH or 2640 casement.

PLUMBING PLANS:

1. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate water meter size.

MECHANICAL PLANS:

1. Provide demand calculations in accordance with Manual J/S/D standards, M1401.3, M1601.1. Systems shall be sized in accordance with Manual S based on building loads calculated in accordance with Manual J and duct systems sized in accordance with Manual D.
2. Show the HVAC system size for the building demand in accordance with M1401.3, M1601.1.

ELECTRICAL PLANS:

1. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3.

OUTDOOR LIGHTING CODE

1. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3.

Please contact the plans reviewer if you have any questions:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
04/07/2025 Site Engineering - Standard REQUIRES RESUBMIT TC-RES-0225-01105
1640 E 8TH ST - UNIT 1

This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://tdc-online.tucsonaz.gov/#/home

Instructions:
1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record
2. Locations -> Confirm the location is accurate to the project. Click “Next”
3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next”
4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next”
5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next”
6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next”
7. 7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next”
8. Review and Submit -> Review all information to ensure accuracy. Click “Submit”

NOTE: Documentation of a cost estimate from your contractor will be required if this project involves any reconstruction, repair, rehabilitation, structurally connected addition, or other improvement of an existing structure (including TIs and solar).

Chris Arrington
chris.arrington@tucsonaz.gov
03/12/2025 PDSD Application Completeness Express REVIEW COMPLETED It appears the uploaded document CONS-Klaimy Project_v1.pdf lists two units: A and B. Please note, each unit requires its own permit application. This permit TC-RES-0225-01105 is for the identified main address 1640 E 8TH ST UNIT 1 TUCSON, AZ 85719. Please submit a new application for Unit 2.
04/04/2025 Site Zoning - Standard REVIEW COMPLETED PDSD TRANSMITTAL

FROM: Jeffrey W. Cassidy, Planner
Planning & Development Services Department – Zoning Review Section

PROJECT: TC-RES-0225-01105 – Residential Building – Remodel SFR Interior into Duplex “A”. See TC-RES-0425-01702 for Unit “B” (Plan set in main permit TC-RES-0225-01105)
1640 E 8th St Unit 1 Tucson, AZ 85719 (NR-2 Zoning)
Building Plan Review - 1st Revision Review

TRANSMITTAL DATE: April 04, 2025

This site is in the NR-2 zone (UDC 5.10.3). A duplex is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6 .9., & .10.

1. COMMENTS: Zoning acknowledges the proposed revisions listed in the drawing package but cannot approve until a design review has been performed by the Neighborhood Preservation team.

If you have any questions about this transmittal, please contact Jeffrey W. Cassidy at jeffrey.cassidy@tucsonaz.gov.