Permit Number: TC-RES-0225-01093
Parcel: 126134600

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0225-01093
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/03/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/03/2025 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT ACTIVITY NO. TC-RES-0225-01093
ADDRESS/PARCEL: (4542 E DOUGLAS ST TUCSON, AZ 85711)
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter.
COMMENTS:
1. Provide a complete gas piping template showing the connection and length from the meter to all attached appliances, G2401.1, R301.1: Include pipe size, pipe material (Black Iron, Poly) and length. Provide appliance demands, G2413.4.1. Provide a template for both addresses.
a. Size the pipe based on the length from the meter to the farthest attached appliance and max total demand of all attached appliances using Table G2413.4(1) (Metallic Pipe), Table G2413.4(7) (Polyethylene Plastic Pipe). Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1.
b. Please state the pipe depth as well, G2415.12.