Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0225-01085
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/27/2025 | Site Zoning - Standard | APPROVED | |||
| 04/01/2025 | Historic - Standard | NOT REQUIRED | The property is a contributor to the Sam Hughes National Register Historic District. As a contributor to the district, the property is eligible for a property tax reduction if it is owner-occupied. As a National Register district, you are not required to go through the City of Tucson Historic Preservation Office (HPO) for work. However, to remain a contributing property, I would recommend that you contact that State Historic Preservation Office (SHPO) to discuss any proposed exterior renovations. They can be reached at 602.542.4009. NO HPZ REVIEW REQUIRED Contact Michael.Taku@tucsonaz.gov |
||
| 04/02/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 04/02/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/03/2025 | Addressing Validation | REQUIRES RESUBMIT | The plans submitted shows to be for Accessory Dwelling Unit. The address location does not have ADU attached to the address. Unit # will have to be confirmed and assigned to Permit Application and on Plans prior to issuance. Once Zoning approves the 2nd unit contact Pima County Addressing to resolve issue Addressing@pima.gov or 520-724-9512. Please submit a comment letter and Plans (with unit #). | ||
| 03/27/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0225-01085 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. GENERAL COMMENTS : 1. All plans submitted for a newly constructed one- or two-family dwelling after June 1, 2010, must provide gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. Provide gray drain-line discharge of the second story bathing fixture through an exterior-wall drop for future gravity distribution. Include an aliened purple colored 2” vertical drop to a cleanout cap 2’ above grade. Remove the first floor detail and use the appropriate second floor detail at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Water-Energy-Conservation Gray Water Illustrations SITE PLAN: 1. Show the new yard water pipe sized for serving both dwellings, R106.1.1. PLANS: 1. Notate a cool (white) roof finish (greater than 60 SRI) as required by the ADU provisions. OUTDOOR LIGHTING CODE 1. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 03/03/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |