04/02/2025 Site Engineering - Standard NOT REQUIRED
04/02/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/01/2025 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0225-01072
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes.

Provide a response letter on separate file when submitting the updated construction plan set.

Structures built without a permit may require alteration for building code compliance. Construction plans are required for determining code compliance before a permit can be issued for the inspection.

Field welding requires a completed special inspection request form for review with the permit plans, R109.2. Obtain an inspector and provide a certified inspector seal on the form found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Inspections

The roof structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by removing the NE Carport placed within 3 feet to the property line or provide a complete wall barrier with not less than one-hour fire-resistive construction in compliance with IBC Table 721.1(2).

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review
04/02/2025 Site Zoning - Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Bobby Parsons
Zoning Section Review

PROJECT: TC-RES-0225-01072
132 S Melrose Ave Tucson, AZ 85745
New permit for existing accessory structures – 2 carports and 1 shade structure (1st Review)

TRANSMITTAL DATE: 4/2/2025

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: We acknowledge an email was included in TC-RES-0924-05262 from Jesus Villezcas for constructing the carport in the drainage easement. Please include that email in the next submittal and include a keynote on site plan stating “The Storm drain Manhole is still accessible for maintenance since it is outside the fence (per google street view). Access to the existing Drainage Easement will need to be maintained for COT. If existing structures in the drainage easement conflict with future drainage improvements or maintenance, they will be removed at no cost to the city.”
2. Comment: Both of the unpermitted carports will require approval through the Design Development Option (DDO). Site zoning is unable to approve this permit until the DDO has been approved.

Comment: The following comments are related to an application for a Design Development Option (DDO) (UDC 3.11.1).
a. The minimum setback in the R-2 zone is the greater of six (6) feet or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). The minimum setback to the front street perimeter property line is twenty (20) feet. Based on a proposed height of 8’ for the northeast carport, the minimum required setback to the north property line is 6’ and 20’ to the front street. The proposed carport setback along the north property line is 1.3’ and 1.7’ along the east property line (front street). The proposed setback will require approval through the DDO application process. Please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov or Mark Castro at Mark.Castro@tucsonaz.gov if you have questions about the DDO process.
b. The minimum setback in the R-2 zone is the greater of six (6) feet or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). The minimum setback to the side street property line is ten (10) feet. Based on a proposed height of 8’ for the south carport, the minimum required setback to the south property line 10’. The proposed carport along the south property line is 1’. The proposed setback will require approval through the DDO application process. Please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov or Mark Castro at Mark.Castro@tucsonaz.gov if you have questions about the DDO process.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
03/04/2025 PDSD Application Completeness Express REVIEW COMPLETED
03/24/2025 ROW Engineering Review - Standard REVIEW COMPLETED Approved with conditions