Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0225-01055
Parcel: 136091600

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-0225-01055
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/27/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/27/2025 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT ACTIVITY NO. TC-RES-0225-01055
ADDRESS/PARCEL: (10772 E MICA MEADOW DR)

COMMENTS:
1. We spoke on the phone and got the 1"1/4" pipe sizing from Joe which under Table G2413.4(1) of the 2018 IRC would be correct when using blackIron. Unfortunately, the CSST is sized under Table G2413.4(5) for Corrugated Stainless Steel Tubing and at 1"1/4" which is the equivalent of Tube size 37 can only support half of the demand required by the 400k BTU pool heater. Please consult TABLE G2413.4(5) [402.4(15)]CORRUGATED STAINLESS STEEL TUBING (CSST) under Chapter 24 of the 2018 IRC .
2. Please resubmit with the correct tube sizing per the code.

Should you have any questions about these comments, I can be reached at Zane.Aouane@tucsonaz.gov
02/26/2025 PDSD Application Completeness Express REVIEW COMPLETED