Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0225-01001
Parcel: 131113000

Address:
5741 E 34TH ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0225-01001
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/01/2025 Site Engineering - Standard NOT REQUIRED
04/01/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/27/2025 Site Zoning - Standard REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-0225-01001
5741 E 34TH ST. – R-1
ADD 36' x 10' PATIO (1st Review)

TRANSMITTAL DATE: March 27, 2025

COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9.

1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example, to include but not limited to:
a. The plot plan shall be drawn at an engineering scale, i.e. 1”=10’, 1” = 20’.
b. The lot coverage calculation is not complete, provide the percentage of lot coverage.
c. Provide a dimension from the center line of 34th to the face of curb, and from the face of curb to the south property line. Per Construction Plan I-689 sheet 22 found at: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-689, the distance from center line of the street to the face of curb is 16’ and from face of curb to the property line is 9’-0”.
d. Provide the legal description, “MARYVALE MANOR LOT 26 BLK 13” on the plot plan.

2. Per UDC Article 6.4.5.B.2 the perimeter yard setbacks for a porch type structure are measured from the post supporting that structure. Clearly show the porch post on the plot plan and provide street perimeter yard setbacks from the post to the street property line.

3. Provide a perimeter yard setback from the post supporting the post to the west property line.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
03/01/2025 PDSD Application Completeness Express REVIEW COMPLETED
03/27/2025 Residential Building - Standard REVIEW COMPLETED