Permit Number: TC-RES-0225-00975
Parcel: 120020530

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0225-00975
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/02/2025 Site Engineering - Standard NOT REQUIRED
04/02/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/03/2025 Addressing Validation REQUIRES RESUBMIT The project address 714 W PRESIDENT ST TUCSON, AZ 85714 was not provided on all pages of your submitted document CONS-714 W PRESIDENT (1)_v1.pdf. Please resubmit your plans and provide the complete address of proposed work on all construction plans pages once all of your reviews are completed.

For questions: building_official@tucsonaz.gov

Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf
03/27/2025 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0225-00975
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes.

Provide a response letter on separate file when submitting the updated construction plan set.

SITE PLAN:

1. Indicate the location of the proposed building and existing overhead electrical line, R106.1.1. Show the utility lines requiring relocation.
2. The carport roof structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by removing the roof placed within 3 feet of the property line or include a complete wall barrier below the roof without openings with not less than one-hour fire-resistive construction in compliance with IBC Table 721.1(2).

SECTIONS - DETAILS:

1 Provide a complete cross-section detail with ridge beam to foundation load path including fasteners, R407.3 & R507.4.1.
2 Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended.

ELECTRICAL PLANS:

1. Show any electrical alterations.
2. The overhead service conductor over the proposed building requires an 8’ clearance above the roof, E3604.2.1. Check with TEP customer service for service line options. https://www.tep.com/electric-service-requirements

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review
03/27/2025 Site Zoning - Standard REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-0225-00975
714 W PRESIDENT ST. – R-2
ADD Porch And Carport (1st Review)

TRANSMITTAL DATE: March 27, 2025

Provide a detailed comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal.

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.

1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example, to include but not limited to:
a. The plot plan shall be drawn at an engineering scale, i.e. 1”=10’, 1” = 20’.
b. Provide a lot coverage calculation the meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements.
c. Provide a dimension from the center line of President St to the face of curb, and from the face of curb to the south property line. Per Construction Plan I-823 sheet 2 found at: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-823, the distance from center line of the street to the face of curb is 18’ and from face of curb to the property line is 12’-0”.
d. Provide the zoning of all adjacent parcels on the plot plan.
e. Provide the property line dimensions on the plot plan.
f. Show all existing utility lines on the plot plan
g. Provide a perimeter yard setback from columns of the carport to the east property line.

2. The side and rear perimeter yard setbacks shown on the plot plan are not correct. Review UDC Table 6.3-2.A and provide the correct required setback or remove the setback lines from the plan.

3. The front street perimeter yard setback shown on the plot plan is not correct. Review UDC Article 6.4.5.C.1.a and provide the correct required setback or remove the setback lines from the plan.

4. The “SETBACKS” shown under “PROJECT INFORMATION” are not correct.

5. Under Energy Compliance note 17 you list “NOTE: SET OF PLANS ARE FOR EXISTING GARAGE”, remove this reference from the plan as it is not applicable.

6. Provide black and white plans as some of the colors are difficult to read.

COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Where the wall meets the eave of the roof. As height dimensions from design grade were not provided Zoning has added 6” to the heights provided.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).

1. Based on a wall height of 9’-6” the required perimeter yard setback from the proposed porch to the west property line is 6’-4”, Proposed setback is 5’-0”.

2. Based on a wall height of 6’-2” the required perimeter yard setback from the proposed carport to the east property line is 6’-0”, Proposed setback was not provided.

3. Per UDC Article 6.4.5.C.1.a the required front street perimeter yard setback is 20’-0”, proposed front street perimeter yard setback is 13’-6”.

A Design Development Option (DDO) must be submitted and approved to reduce the required setbacks. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
03/03/2025 PDSD Application Completeness Express REVIEW COMPLETED