Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0225-00931
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/27/2025 | Site Zoning - Standard | APPROVED | |||
| 04/01/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 04/01/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/24/2025 | Residential Building - Standard | REQUIRES RESUBMIT | Provide manufacturer’s calculations and data for engineered trusses sealed by a registered in Arizona engineer, or notate the requirement for deferred submittal, R106.1. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Identify the ventilation requirements and insulation types for complying with the condensation control issues. |
||
| 02/27/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |