Review Date Reviewer's Name Type of Review Description Status Comments
03/27/2025 Site Zoning - Standard APPROVED
04/01/2025 Site Engineering - Standard NOT REQUIRED
04/01/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/24/2025 Residential Building - Standard REQUIRES RESUBMIT Provide manufacturer’s calculations and data for engineered trusses sealed by a registered in Arizona engineer, or notate the requirement for deferred submittal, R106.1.

Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Identify the ventilation requirements and insulation types for complying with the condensation control issues.
02/27/2025 PDSD Application Completeness Express REVIEW COMPLETED