Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0225-00748
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/27/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 03/27/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/24/2025 | Design Review - Standard | REQUIRES RESUBMIT | Work requiring a building permit is visible from the Right-of-Way. Neighborhood Preservation Zone design review will be required. An overview of the design review process can be found here: https://www.tucsonaz.gov/files/sharedassets/public/v/3/pdsd/documents/planning-amp-zoning/npz-application-and-review-process-1.pdf A checklist of design review submittal requirements and descriptions can be found here: https://www.tucsonaz.gov/files/sharedassets/public/v/3/pdsd/documents/submission-documents/special_districts_application_instructions_7.18.23.pdf A Special Districts application can be submitted through the "Requests" tab in your permit while logged into TDC Online. |
||
| 03/17/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0225-00748 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections. Note the 2018 IRC reference on the plans. Provide a clear and concise construction plan set. Sample drawings are available for understanding details. Sample plans at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits PLANS: 1. Provide a Roof Framing Plan showing the rafters sized for supporting live and dead structural loads (Table R802.4.1(1)) or provide an engineer’s sealed plan set for manufactured trusses, R301.1.3. SECTIONS - DETAILS: 1. Provide a wall section detail with (#4 rebar) reinforced 12” x 12” reinforced foundations for anchoring exterior framed (insulated) walls with pressure treated sills including ½” anchor bolts with 7” embedment, R403.1.6. 2. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5). The weep screed may extend with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1. 3. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. 4. Show the minimum 12”x12” by 12” deep #4 reinforced footing in undisturbed ground supporting each post with 1” gap post base hardware, R403.1. 5. Provide structural roof sheathing size and fastening in compliance with Table R602.3 (1). 6. Note the location and size of ledger anchorage to a load bearing wall, R606.11. Remove any stucco behind the ledger. 7. Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. PLUMBING PLANS: 1. Show the water heater rating if proposed as a new unit, P2801.1. 2. Show any gas pipe alterations with segments sized in conformance with Table G2413.4(1). Existing gas pipes may require upgrading with this system alteration. MECHANICAL PLANS: 1. Show the HVAC system size accordance with M1401.3, M1601.1. 2. Provide demand calculations in accordance with Manual J/S/D standards, M1401.3, M1601.1. ELECTRICAL PLANS: 1. Designate the circuit number at the location of each light fixture, receptacle, appliance, and equipment disconnect switch, R106.1.1. 2. Provide a panel schedule showing panel size, circuit numbers, ampacity, wire size and general description of proposed outlets, E3404.13 & E3706.2. 3. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. 4. Show Bathroom receptacles with a separate 20 AMP dedicated circuit, E3703.4 and E3901.6. 5. Interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. Add notation to plans. OUTDOOR LIGHTING CODE 1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services ---------------------- |
||
| 03/20/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-RES-0225-00748 1215 N Euclid Ave Tucson, AZ 85719 Renovate SFR; Closet and Porch Addition (1st Review) TRANSMITTAL DATE: 3/20/2025 This site is located in the NR-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: The site plan should be designed to include the information as noted on the sample site plan. Please see https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf for reference. 2. Comment: Per UDC 6.4.3.C.1, “Roofed areas, open on at least one side, which provide shelter to exterior areas such as balconies, entrances, stoops, and terraces, provided they are not used for utilities, maintenance, laundry, storage, or motor vehicle parking are excluded from lot coverage calculations.” Please remove the existing covered porch from your lot coverage calculations and update the calculations. 3. Comment: The zone listed on your site plan is R-1, however the correct city of Tucson zone is NR-1. Please update. 4. Comment: Please add the surrounding zoning classification as noted in the sample site plan. This property is surrounded by the NR-1 zone. 5. Comment: Please draw, label, and dimension the ½ ROW from the centerline of Euclid Ave to the face of curb and from the face of curb to the property line. Refer to paving plan I-75-020 if necessary. https://maps-and-records.tucsonaz.gov/construction-plans/details/I-75-020. 6. Comment: Please list the legal description on your site plan which should read “Feldmans Amended N95’ Lots 19 & 20 Blk 12”. 7. Comment: The minimum front street setback is listed as 21’ on the site plan, however the minimum front street setback should be 20’. Please update. 8. Comment: This site is located in Feldmans Historic District. Neighborhood Preservation Zone (NPZ) review and approval is required prior to zoning approval. 9. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 02/21/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |