Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-0225-00721
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/20/2025 | Historic - Standard | NOT REQUIRED | The property at 2409 E 5th Street is a contributor to the Sam Hughes National Register Historic District. As a contributor to the district, the property is eligible for a property tax reduction if it is owner-occupied. As a National Register district, you are not required to go through the City of Tucson Historic Preservation Office (HPO) for work. However, to remain a contributing property, I would recommend that you contact that State Historic Preservation Office (SHPO) to discuss any proposed exterior renovations. They can be reached at 602.542.4009. You will want to talk to either Susan Lawson, slawson@azstateparks.gov 602- 542-6943. NO HPZ REVIEW REQUIRED Contact Michael.Taku@tucsonaz.gov |
||
| 04/21/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/20/2025 | Residential Building - Standard | REQUIRES RESUBMIT | |||
| 03/20/2025 | Site Engineering - Standard | REQUIRES RESUBMIT | |||
| 04/21/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-RES-0225-00721 2409 E 5TH ST. – R-1 Deck Cover (1st Review) TRANSMITTAL DATE: April 21, 2025 This comment was not addressed. Resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 – 9. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. As height dimensions from design grade were not provided Zoning has added 6” to the heights provided on the plan. Per UDC Article 6.4.5.B.2 A vertical structural member(s) (i.e., post, column, dormer wall) supporting a roof extension from the principal structure is considered a wall for applying perimeter yard requirements. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). 1. Based on a wall height of 18’-10” the required perimeter yard setback from the proposed deck cover to the north property line is 12’-7”, proposed setback is 4’-2”. 2. As a wall height was not provided for the area were the roof structure is connected to the main structure Zonin has used a measurement function in the PDSD review software, Bluebeam. Based on a wall height of 21’-1” the required perimeter yard setback from the proposed deck cover to the east and west property line is 14’-1”, proposed setback to the east property line is 7’-4” and to the west property line is 8’-9”. A Design Development Option (DDO) will need to be submitted and approved. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process, please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov |
||
| 04/21/2025 | Zoning Modifications - DDO - Standard | REQUIRES RESUBMIT | FROM: Georgia Pennington, Planner DATE: 4/21/25 COMMENTS: 1. The submitted DDO application has been deemed complete by staff. If the DDO is approved, provide a copy of your DDO decision letter in addition to a revised plan set and a comment response letter. Please contact me at Georgia.Pennington@tucsonaz.gov or at 520-837-6311 should you have questions about this transmittal. |
||
| 03/20/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |