Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0224-01211
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/01/2024 | Fire New Construction | NOT REQUIRED | |||
| 03/18/2024 | Site Engineering | NOT REQUIRED | |||
| 04/02/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/11/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0224-01211 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. SITE PLAN: Provide a site plan showing dimensions of buildings and utilities, R106.1.1. Show the location of utility lines from property line to building(s) along with required alterations. STRUCTURAL PLANS: 1. Provide a complete roof framing plan with beams and rafters sized with appropriate prescriptive load carrying capacity, R301.1 or provide an engineer’s sealed plan set for performance compliance consideration, R301.1.3. The 4x6 roof supporting beam is undersized. SECTIONS - DETAILS: 1. Show a complete cross-section detail of the new exterior wall, R106.1.1. Show a pressure treated sill with wall sheathing at 6” clearance above the ground, R317.1 item 5. Show a garage frame wall supported with a level foundation stem and sloping floor. 2. Specify the minimum thickness (1/2”) of non-structural siding, R602.10.3.4, and a #15 water-resistive barrier over studs/sheathing of all exterior walls, R703.2. OSB may be 3/8” thickness as a structural sheathing but requires stucco covering. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 04/02/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Nathan Herrera Lead Planner PROJECT: TC-RES-0224-01211 Address: 10321 E Calle Del Este. Tucson, AZ. 85748 Parcel: 133-38-0800 Zoning: RX-1 Existing Use: Single Family Residence Project Description: Carport enclosure/addition TRANSMITTAL DATE: 04/02/2024 This site is located in the RX-1 zone (UDC 4.7.6). A single-family residence is permitted use in this zone (Table 4.8-1) subject to Use Specific Standards 4.9.7.B.6,9,10. 1. COMMENT: Provide a Lot Coverage Calculation that meets the requirements found at the below example. https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf 2. COMMENT: Provide dimensions and setbacks for the Existing Shed shown on the site plan. Nathan.Herrera@tucsonaz.gov |
||
| 02/29/2024 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 03/18/2024 | Site Landscape | REVIEW COMPLETED |