Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-0224-01207
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/16/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/25/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0224-01207 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Provide a response letter on separate file with the updated construction plan set. Consider using a design professional if unfamiliar with construction documentation. SITE PLAN: Provide a site plan showing utilities for the dwelling, R106.1.1. Show the location of all utility lines from property line to building(s) along with required alterations including utility lines between buildings. STRUCTURAL PLANS: 1. Provide a complete plan set showing materials and fastener sizes with 2018 IRC prescriptive compliance or provide an Arizona professional stamped plan set showing performance compliance with wind loading conditions, R301.1. SECTIONS - DETAILS: 1. Provide a structure section showing proposed features including foundation, reinforcement and anchoring, R106.1. PLUMBING PLANS: 1. Show any proposed changes, R301.1. MECHANICAL PLANS: 1. Show any proposed changes, R301.1. ELECTRICAL PLANS: 1. Provide a Riser Diagram showing a sub panel and feeder size for proposed alterations, NEC 225.30, E3403, Table E3704.2(1). 2. Designate the circuit number at the location of each light fixture, receptacle, appliance, and equipment disconnect switch, E3404.12. 3. Provide a panel schedule showing panel size, circuit numbers, ampacity, wire size and general description, E3404.13 & E3706.2. Provide proposed wiring details showing code compliant device locations and circuit sizes. OUTDOOR LIGHTING CODE Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 07/16/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0224-01207 2723 E DRACHMAN ST. - R-1 Detached Shop (2nd Review) TRANSMITTAL DATE: July 16, 2024 Provided a detailed comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9. The following comments are based on sheet 5, Existing Site Plan: 1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example, to include but not limited to: a. This comment was not addressed correctly. Per UDC Article 6.4.3.C.1.a Roofed areas, porches, open on at least one side are not included in the calculation. Provide a lot coverage calculation that meets the requirements of Unified Development Code (UDC) Article 6.4.3 and the example shown on the Residential Plot Plan Requirements. b. This comment was not addressed correctly. The north/south property dimension should be 142.5’Provide the property dimensions on the plot plan. 2. This comment was not addressed correctly. Gross floor area does not include porches or carports. Based on the square footage shown when the porches and carport are removed from the total floor area the shop exceeds the allowed 50%. A Board of Adjustment for Variance is required. UDC Per UDC Article 6.6.3.E the total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure. Accessory structures less than 200 square feet gfa and accessory dwelling units are exempt from this requirement. Gross floor area is defined as The sum of the horizontal areas of all floors of all buildings , including accessory buildings on a lot , measured from the exterior faces of the exterior walls or from the centerline of walls separating two buildings and includes elevator shafts and the stairwells at each story. Gross floor area includes floor space with structural headroom of six feet and six inches or more used for mechanical equipment; penthouses; attic space; interior balconies; mezzanines; and service bays but does not include any interior space used for parking, loading, or loading space that is incidental to the principal use. Provide the gross floor area for the existing residence and a calculation that demonstrates what percentage of the residence gfa the proposed shop is. If the shop exceeds 50% a Board of Adjustment for Variance will be required. 3. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Per UDC Table 6.3-2.A the required perimeter yard setback from the proposed shop to the north and west property line is 6’-0” or 2/3 (H), (H) = Height of the proposed exterior building wall, great of the two dimensions apply. Based on a wall height of 14’-6” the required perimeter yard setback form the proposed shop to the north and west property line is 9’-9”, proposed setbacks to the north and west property line are 5’-0”. The reduced setbacks can be dealt with in one of 3 ways. 1) Provide a neighbors setback waiver, see requirements below. 2) Submit a Design Development Option (DDO), see requirements below. 3) If you end up applying for the Board of Adjustment the reduces setbacks and be included in the process. To avoid two separate processes either provide the neighbors setback waive or include the reduced setbacks in the Board of Adjustment. Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-2. Contact for the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov. To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s): My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code#section-1. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 06/18/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |