02/26/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-0224-01041 (3408 E MONTE VISTA DR Unit:BLDG 0 UNIT 1 TUCSON, AZ 85716)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC).

>>> The following comments were not addressed:
1. Show each pipe segment sized in conformance with Table G2413.4(1). A system with 200,000 BTU demand and 163 developed length requires 1-1/4" pipe between the meter and first branch tee. Review the Gas Work documents at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits
2. Provide the type of pipe being used, Black Iron, PEX, ect, G2413.4.1
3. Yellow tracer wire required for non-metallic pipe, G2415.17.3.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
02/26/2024 PDSD Application Completeness Express REVIEW COMPLETED