Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.2
Permit Number - TC-RES-0224-01041
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/26/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/26/2024 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-0224-01041 (3408 E MONTE VISTA DR Unit:BLDG 0 UNIT 1 TUCSON, AZ 85716) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). >>> The following comments were not addressed: 1. Show each pipe segment sized in conformance with Table G2413.4(1). A system with 200,000 BTU demand and 163 developed length requires 1-1/4" pipe between the meter and first branch tee. Review the Gas Work documents at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits 2. Provide the type of pipe being used, Black Iron, PEX, ect, G2413.4.1 3. Yellow tracer wire required for non-metallic pipe, G2415.17.3. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 02/26/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |