Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0224-00899
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/28/2024 | Fire New Construction | NOT REQUIRED | |||
| 03/12/2024 | Site Engineering | NOT REQUIRED | |||
| 03/21/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/28/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0224-00899 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The application was accepted for a Sleeping Quarters. Therefore, remove the kitchen or show the guest house as an ADU and comply with dwelling unit requirements. Clarify if the structure is a sleeping quarters (without kitchen) or an Accessory Dwelling Unit (ADU) which requires many alterations for compliance. Each dwelling unit with kitchen requires a separate Pima County assigned street address after Zoning approval, R319. https://www.pima.gov/1010/Addressing-Frequently-Asked-Questions An impact fee payment is required for an ADU at the time of permit payment. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc. SITE PLAN: 1. Show the location and size of buildings, utility meters and gas, water, electrical, and sewer, R106.1.1. Each dwelling requires an appropriate source of electrical and water supply. Show the location and size of lines with connection points, R106.1.1. Identify the utility lines requiring upgrade or replacement. PLANS: 1. Notate a cool (white) roof finish as required by the ADU provisions. 2. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1. Include all threshold conditions for a route from the exterior into the living space. SECTIONS - DETAILS: 1. Show the floor height with a 4” clearance above the ground, R317.1. Update detail #1 sheet 1. PLUMBING PLANS: 1. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate yard pipe for supporting the existing and proposed dwellings and show an appropriate water meter size. 2. Show an individual accessible water supply shut off and water heater for the proposed dwelling unit, P2903.9.1. MECHANICAL PLANS: 1. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation with controlled exhaust, R303.4; N1103.6 & M1505.4. Show the minimum airflow rate setting and location of the device requiring this adjustable setting. A one bedroom dwelling under 1501 SF requires a 30 CFM continuous setting. 2. Provide demand calculations in accordance with Manual J standards, M1401.3, M1601.1. ELECTRICAL PLANS: 1. Provide a minimum service conductor rating of 100 AMP for each dwelling and conductors with minimum rating of #3 copper 75 degree C, E3602.1 & E3603.1. Update the Riser Diagram and panel schedule. 2. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. Separate the countertop receptacle from the refrigerator circuit. OUTDOOR LIGHTING CODE 1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 03/21/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Nathan Herrera Planner PROJECT: TC-RES-0224-00899 Address: 10442 E Calle Trece. Tucson, AZ. 85748 Parcel: 133-38-1350 Zoning: RX-1 Existing Use: Single Family Residence Project Description: Accessory Dwelling Unit TRANSMITTAL DATE: 3/21/2024 This site is located in the RX-1 zone (UDC 4.8.3). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .8 & .9. 1. COMMENT: Clarify whether the proposed structure is to be a Sleeping Quarters or an Accessory Dwelling Unit (ADU). If the proposed structure is to be a Sleeping Quarter the full kitchen shown on the floor plan will have to be modified. A sleeping quarters cannot contain a full range and oven. If the proposed structure is to be an ADU, UDC Article 6.6.3.B will be required. Specifically show where the one required parking space will be located on the property, and how the structure will be developed with a high albedo level (>60 SRI) or other cool roof technology per the ICC Green Construction Code. 2. COMMENT: Per UDC Article 6.3-1.A, the required setbacks in the RX-1 zone are 20 feet as measured from the property line. The proposed structure encroaches into the required setback. If the structure is to be a Sleeping Quarters a neighbor’s setback waiver may be utilized to reduce the required setback. The neighbor waiver shall be signed by the property owners of Pima County Tax Parcels Number 133-38-1340, 133-38-1350 and 133-38-1240. The signed neighbor waivers shall be directly pasted on the site plan and shall include the following text: My name is ______ and I am the owner of the property located at ______. I have reviewed the site plan and I have no objection to the structure being located or construct __ feet from the property line as depicted on the site plan. Signature: ________ Date: _________ If a neighbor waiver cannot be obtained, or the proposed structure is to be an ADU a Design Development Option must be applied for and approved before this permit can be approved by Zoning. A neighbor waiver cannot be used for an ADU. A Design Development Option (DDO) must be applied for and approved in order to reduce the setbacks as proposed before this permit can be approved by Zoning. The below paperwork can be filled out and submitted with the next submission. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/2019_ddo_for_setback_and_height_udc.pdf For more information about the DDO process contact Wyatt Berger at wyatt.berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: revised residential building permit along with a detailed response letter, which states how all Zoning Review Section comments were addressed. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf If you have any questions about this transmittal, please contact Nathan Herrera at Nathan.Herrera@TucsonAZ.gov or at 520-837-4894 |
||
| 02/23/2024 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 03/14/2024 | Site Landscape | REVIEW COMPLETED |