Permit Number: TC-RES-0224-00768
Parcel: 125050820

Address:
2409 E 5TH ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0224-00768
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/13/2024 Fire New Construction NOT REQUIRED
02/29/2024 Site Engineering NOT REQUIRED
03/05/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/14/2024 Residential Building REQUIRES RESUBMIT Provide a complete construction plan set showing 2018 IRC compliance after DDO approval.

Clarify existing from proposed construction on the site plan. Also, include the utilities.
03/05/2024 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-0224-00768
2409 E 5TH ST. – R-1
Attached 2nd Dwelling Unit w/ Garage (1st Review)

TRANSMITTAL DATE: March 5, 2024

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9

1. The perimeter yard indicator “AA” shown under Perimeter Yard is no longer valid and was removed from the code in 2011. Remove the indicator from the plan.

2. The front street perimeter yard setback “or 1-1/2 Height” shown is not correct and was removed from the code in April of 2023, UDC Article 6.4.5.C.1.a. Remove the reference to or 1-1/2 Height from the plan.

3. As the second floor dwelling unit does not meet the requirements of UDC Articles 6.6.3.B.5 & 6.6.3.D it cannot be considered an Accessory Dwelling Unit (ADU) and is considered a a 2nd dwelling unit. Per UDC Table 4.8-2, Residential Land Use Group With Land Use Class/Type: Single-family, Detached, R-1 Zone the minimum lot size for 2 dwelling units is 10,000 sf. A rezoning will be required.

4. The plot plan shall be drawing at an engineering scale, i.e. 1” = 10’, 1” = 20’.

5. Provide a dimension from the center line of 5th street to the face of curb and from the face of curb to the south property line.

6. Provide a height dimension from design grade to the top of wall at the garage on the north elevation.

7. Provide a height dimension from design grade to the top of wall at the top of the second floor wall of the 2nd dwelling unit on the north elevation.

8. Provide a setback dimension from the north second floor wall to the north property line.

Once the above comments are addressed Zoning will be able to provide applicable Design Development Option (DDO) comments.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
02/09/2024 PDSD Application Completeness Express REVIEW COMPLETED
02/27/2024 Site Landscape REVIEW COMPLETED