Permit Number: TC-RES-0224-00745
Parcel: 116214250

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.2

Permit Number - TC-RES-0224-00745
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/13/2024 Site Zoning APPROVED
03/05/2024 Site Engineering NOT REQUIRED
03/13/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/15/2024 Residential Building REQUIRES RESUBMIT TC-RES-0224-00745
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

SITE PLAN:

1. Provide a site plan showing the location of the electrical service panel, R106.1.1.

SECTIONS - DETAILS:

1. Provide a structure section showing existing and proposed floor features, R106.1. Show alterations to include R-13 insulation between the garage ceiling and floor surface.
2. Show existing and proposed 5/8” type X gypsum board at the garage beneath habitable rooms, Table R302.6.
3. Clarify if additional roof venting is required for compliance with R806.2. The attic space outside of the thermal barrier requires total ventilation opening size using 1 to 150 of attic area.

ELECTRICAL PLANS:

1. Notate new and extended interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors require combination type arc-fault circuit interrupters, E3902.16 & 17.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
02/13/2024 PDSD Application Completeness Express REVIEW COMPLETED