Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0224-00618
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/12/2024 | Residential Building | APPROVED | |||
| 02/28/2024 | Site Engineering | NOT REQUIRED | |||
| 02/28/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/08/2024 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-0224-00618 (5390 S SOUTHERN OAK DR TUCSON, AZ 85746) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. Provide a beam sized to support the imposed loads, R301.1. The 6x10 Hem-Fir #2 (Beam specification sheet A-3) beam is undersized for the given tributary loads. 2. Provide consistent sizing information for the new beams. Details 9 and 10, sheet S-1, show a 6x8 beam while detail 7, sheet S-1, shows a 6x10 beam. 3. Clarify detail 8 Sheet S-1. Is the 2x12 rafter extending over the wall with the H2.5 attachment? Or is it attached to the 2x Frieze board? 4. Provide a detail of the ledger called out in Framing Plan Keynotes #3, see Sheet S-1, R106.1, R301.1. Show ledger to wall connections consistent with Figure R606.11 (1). 5. For wind uplift use 115 mph in 3sec gust, Table R301.2(1) (see Sheet A-3, wind load). https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 02/05/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Georgia Pennington Planner PROJECT: TC-RES-0124-00279 5390 S Southern Oak Dr (Porch) (1st Review) TRANSMITTAL DATE: (2/5/24) This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, 9, & 10. 1. Clarify whether site plan keynotes 5, 6, and 7 are attached and provide setback information on the plan for these structures. At a minimum, a signed neighbor's setback waiver from the owner of 1617 W Trendwood Dr is required to reduce the side perimeter yard setback. Signed neighbor's setback waivers from the owners of 5401 and 1625 will also be required if perimeter yards are not currently met. The adjacent owner’s waiver statement must be added to the site plan. The following statement can be used. My Name is __________________ and I am the owner of the property located at ________________________. I have reviewed the site plan and I have no objection to structure being located or constructed ______ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ If a neighbor setback waiver cannot be obtained, a Design Development Option will be required. Please visit the following link for the application: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/2019_ddo_for_setback_and_height_udc.pdf Contact Georgia.Pennington@tucsonaz.gov if you have any questions about this process. 2. Provide setback information from the proposed porch to property lines. If you have any questions about this transmittal, please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov or at 520-837-6311. |
||
| 02/09/2024 | Fire New Construction | REVIEW COMPLETED | |||
| 02/02/2024 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 02/27/2024 | Site Landscape | REVIEW COMPLETED |