Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0223-03007
Parcel: 124032540

Address:
332 N WARREN AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0223-03007
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/14/2023 Site Zoning APPROVED
03/10/2023 Site Engineering NOT REQUIRED
03/20/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
03/20/2023 Residential Building REQUIRES RESUBMIT 1. A dwelling demo requires a separate permit. Update keynote #14/A1.0. Provide a signed Confirmation of Notice of Demolition when obtaining the building demo permit, R104.
2. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. Update details sheet S2.0 and A5.0.
03/01/2023 PDSD Application Completeness REVIEW COMPLETED