Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - TC-RES-0223-02992
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/15/2023 | Residential Building | APPROVED | |||
| 06/15/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/25/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0223-02992 2902 East Malvern Street – R-1 Addition and porch (2nd Review) TRANSMITTAL DATE: May 25, 2023 The following comments are applicable to an application for a Design Development Option (DDO) (UDC 3.11.1) and to an application for architectural documentation prior to demolition of historic buildings (UDC 3.12.1). 2. This comment was not entirely addressed. Per UDC Table 6.3-2.A, when a residential use is adjacent to a residential zone, the required side and rear setbacks are six feet or 2/3 the height of the proposed wall, measured from the property line, whichever is greater. Based on a wall height of 12’-6”, the required setback measured from the east property line to the proposed addition is 8’-4”; proposed is 6’-0”. A DDO is necessary to reduce this setback requirement. Additional comment: According to the Pima County Assessor’s Office, the effective date of construction of the residence is 1949. As it appears the existing family room will be demolished based on the elevation drawings, historic documentation is required to be submitted for historic review and approval: https://www.tucsonaz.gov/files/pdsd/forms/2019_Historic_or_Older_Demo_Documentation_Form_and_Instructions.pdf. Buildings, portions of buildings or structures that are 50 years of age or older must be architecturally documented prior to demolition. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 05/30/2023 | Zoning Modifications - DDO | REQUIRES RESUBMIT | DATE: 5/30/23 FROM: Georgia Pennington, Planner COMMENTS: 1. Address all Site Zoning comments. 2. Zoning has identified an item that requires a Design Development Option (DDO). The DDO application and requirements may be retrieved from: https://www.tucsonaz.gov/files/pdsd/forms/2019_DDO_for_Setback_and_Height_UDC.pdf. The completed application shall be submitted as a PDF under assigned permit number TD-RES-0223-02992. If you have questions about this transmittal, please email me at georgia.pennington@tucsonaz.gov. |
||
| 05/15/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |